IniniiVision 3000 X-Series Oscilloscopes Data Sheet Oscilloscopes redefined: Breakthrough technology delivers more scope for the same budget
Oscilloscopes redefined: Breakthrough technology delivers more scope for the same budget Breakthrough technology for budget conscious customers Overview of the Agilent InfiniiVision X-Series oscilloscopes InfiniiVision 6000 X-Series 4000 X-Series 3000 X-Series 2000 X-Series Analog channels 2 or 4 2 or 4 2 or 4 2 or 4 16 (MSO models or upgrade) 8 (MSO models or upgrade) Digital channels 16 (MSO models or upgrade) 16 (MSO models or upgrade) Bandwidth (upgradable) 1, 2.
Oscilloscopes redefined: Breakthrough technology delivers more scope for the same budget More scope The InfiniiVision 3000 X-Series redefined oscilloscopes. It sees the most signal detail, does more functions than any other oscilloscope, and gives you maximum investment protection. 3000 X-Series – oscilloscopes redefined Key features • See more: ◦ One million waveforms per second update rate The 3000 X-Series’s innovation starts with the industry’s only 5-instruments-in-1 integration.
Oscilloscopes redefined: Breakthrough technology delivers more scope for the same budget See more of your signal, more of the time Largest display The best signal visibility starts with the largest display. The InfiniiVision 3000 X-Series comes with a large 8.5-inch WVGA display so you can view analog, digital and serial signals easily on the screen. Fastest update rate If you can’t see the problem, it is hard to troubleshoot it.
Oscilloscopes redefined: Breakthrough technology delivers more scope for the same budget Do more with the power of 5 instruments in 1 Best-in-class oscilloscope The InfiniiVision 3000 X-Series features up to 4 Mpts of memory with Agilent’s patented MegaZoom IV technology that is always enabled and always responsive providing the industry’s fastest update rate at up to 1 million waveforms per second, with no compromise if you turn on measurements, digital channels or protocol decodes.
Oscilloscopes redefined: Breakthrough technology delivers more scope for the same budget Do more with the power of 5 instruments in 1 Integrated digital voltmeter An industry first, the 3000 X-Series offers an integrated 3-digit voltmeter (DVM) and 5-digit frequency counter inside the oscilloscopes (DSOXDVM).
Oscilloscopes redefined: Breakthrough technology delivers more scope for the same budget Get more investment protection with the industry’s only fully upgradable oscilloscope Upgradability: Add at the time of your purchase or upgrade later: Project needs change, but traditional oscilloscopes are fixed – you get what you pay for at the time of purchase. With the 3000 X-Series, your investment is protected.
Oscilloscopes redefined: Breakthrough technology delivers more scope for the same budget Get more investment protection with the industry’s only fully upgradable oscilloscope Segmented memory When capturing low-duty cycle pulses or data bursts, you can use segmented memory acquisition to optimize acquisition memory.
Oscilloscopes redefined: Breakthrough technology delivers more scope for the same budget Get more investment protection with the industry’s only fully upgradable oscilloscope HDTV video triggering and measurement analysis.
Oscilloscopes redefined: Breakthrough technology delivers more scope for the same budget Other productivity tools Infiniium Offline Oscilloscope Analysis Software (N8900A) Agilent’s Infiniium Offline PC-based analysis oscilloscope software allows you to do additional signal viewing, analysis and documentation tasks away from your scope. Capture waveforms on your scope, save to a file, and recall the waveforms into Infiniium Offline.
Oscilloscopes redefined: Breakthrough technology delivers more scope for the same budget Other productivity tools Reference waveforms Store up to two waveforms in the scope’s non-volatile reference waveform memory locations. Compare these reference waveforms with live waveforms, and perform post analysis and measurements on stored data. You can also store waveforms on a removable USB memory device in *.h5 format and recall them back into scope’s reference waveform memory later.
Oscilloscopes redefined: Breakthrough technology delivers more scope for the same budget Other productivity tools Connectivity and LXI compatibility Built-in USB host (one front, one back) and USB device ports make PC connectivity easy. Operate the scope from your PC and save/recall stored waveforms as well as set-up files via LAN. The optional LAN/VGA module gives you network connectivity and complete LXI class C support as well as the ability to connect to an external monitor.
Oscilloscopes redefined: Breakthrough technology delivers more scope for the same budget Other productivity tools Search and navigation When capturing long complex waveforms using the scope’s deep acquisition memory, manually scrolling through stored waveform data to find specific events of interest can be slow and cumbersome.
Oscilloscopes redefined: Breakthrough technology delivers more scope for the same budget Oscilloscope shown actual size 8.
Search and navigate front panel controls make it easy to find and view specific signal activity quickly play, stop, rewind and fast forward through waveforms Quickly pan and zoom for analysis with MegaZoom IV’s instant response and optimum resolution Autoscale lets you quickly display any analog or digital active signals, automatically setting the vertical, horizontal and trigger controls for the best display, while optimizing memory Dedicated keys for quick access to serial, digital channels, math funct
Oscilloscopes redefined: Breakthrough technology delivers more scope for the same budget Configuring your InfiniiVision X-Series oscilloscope Step 1. Choose your bandwidth, number of channels and memory depth. 3000 X-Series specification overview 3012A 3014A 3024A 3032A 3034A 3052A 3054A 3102A 3104A Bandwidth* (– 3 dB) 100 MHz 200 MHz 350 MHz 500 MHz 1 GHz Calculated rise time (10-90%)” ≤ 3.5 ns ≤ 1.
Oscilloscopes redefined: Breakthrough technology delivers more scope for the same budget Configuring your InfiniiVision X-Series oscilloscope Step 3. Choose your probes - For complete list of compatible probes, see Agilent document 5968-8153EN and visit www.agilent.com/find/scope_probes.
Oscilloscopes redefined: Breakthrough technology delivers more scope for the same budget Performance characteristics DSO and MSO 3000 X-Series oscilloscopes 3000 X-Series specification overview 3012A 3014A 3024A 3032A 3034A Bandwidth * (–3 dB) 100 MHz 200 MHz 350 MHz Calculated rise time (10 - 90%) ≤ 3.5 ns ≤ 1.
Oscilloscopes redefined: Breakthrough technology delivers more scope for the same budget Performance characteristics Horizontal system analog channels 3012A Time base range 3014A 3024A 3032A 3034A 3052A 5 ns/div to 50 s/div 2 ns/div to 50 s/div Time base accuracy* 3054A 1 ns/div to 50 s/div 3102A 3104A 500 ps/div to 50 s/div 25 ppm ± 5 ppm per year (aging) Time base delay time range Pre-trigger Greater of 1 screen width or 250 μs Post-trigger 1 s to 500 s Channel-to-channel deskew range ±
Oscilloscopes redefined: Breakthrough technology delivers more scope for the same budget Performance characteristics Trigger system Trigger sources Analog channel (1~4), digital channel (D0~D15), line, external, WaveGen (1 or mod) (FM/FSK) Trigger modes • Normal (triggered): requires trigger event for scope to trigger • Auto: triggers automatically in absence of trigger event • Single: triggers only once on a trigger event, press [Single] again for scope to find another trigger event, or press [Run] to
Oscilloscopes redefined: Breakthrough technology delivers more scope for the same budget Performance characteristics Trigger type selections Edge Trigger on a rising, falling, alternating or either edge of any source Edge then edge (B trigger) Arm on a selected edge, wait a specified time, then trigger on a specified count of another selected edge Pulse width Trigger on a pulse on a selected channel, whose time duration is less than a value, greater than a value, or inside a time range • Minimum durati
Oscilloscopes redefined: Breakthrough technology delivers more scope for the same budget Performance characteristics Waveform measurements Cursors** • Single cursor accuracy: ±[DC vertical gain accuracy + DC vertical offset accuracy + 0.25% full scale] • Dual cursor accuracy: ±[DC vertical gain accuracy + 0.5% full scale]* • Units: Seconds(s), Hz (1/s), Phase (degrees), Ratio (%) Automatic measurements Measurements continuously updated with statistics. Cursors track last selected measurement.
Oscilloscopes redefined: Breakthrough technology delivers more scope for the same budget Performance characteristics WaveGen – Built-in function/arbitrary waveform generator (specifications are typical) WaveGen out Front-panel BNC connector Waveforms Sine, Square, Ramp, Pulse, DC, Noise, Sine Cardinal (Sinc), Exponential Rise, Exponential Fall, Cardiac, Gaussian Pulse, and Arbitrary.
Oscilloscopes redefined: Breakthrough technology delivers more scope for the same budget Performance characteristics WaveGen – Built-in function/arbitrary waveform generator (specifications are typical) (Continued) Frequency • Sine wave and ramp accuracy: ◦ 130 ppm (frequency < 10 kHz) ◦ 50 ppm (frequency > 10 kHz) • Square wave and pulse accuracy: ◦ [50+frequency/200] ppm (frequency < 25 kHz) ◦ 50 ppm (frequency ≥ 25 kHz) • Resolution: 0.
Oscilloscopes redefined: Breakthrough technology delivers more scope for the same budget Performance characteristics General and environmental characteristics Power line consumption 100 watts Power voltage range 100-120V, 50/60/400 Hz; 100-240V, 50/60 Hz ± 10% auto ranging Temperature Operating: 0 to +55 °C Nonoperating: –30 to +71 °C Humidity Operating: Up to 80% RH at or below +40 °C; up to 45% RH up to +50 °C Non-operating: Up to 95% RH up to 40 °C; up to 45% RH up to 50 °C Altitude Operating: u
Oscilloscopes redefined: Breakthrough technology delivers more scope for the same budget Performance characteristics Nonvolatile storage Reference waveform display 2 internal waveforms or USB thumb drive Waveform storage Setup, .bmp, .png, .csv, ASCII, XY, reference waveforms .alb, .
Oscilloscopes redeined: Breakthrough technology delivers more scope for the same budget License-only bandwidth upgrades and measurement applications Entitlement certificate Stick-0n label sheet Agilent sales partner Agilent software licensing website Customer 5 Email containing attached licensed file USB drive containing license file License Only Bandwidth Upgrade Models Process Description 3000 X-Series DSOX3BW24 100 MHz to 200 MHz, 4 ch, License only DSOX3BW52 350 MHz to 500 MHz, 2 ch, License on
Oscilloscopes redeined: Breakthrough technology delivers more scope for the same budget Return-to-Agilent Service Center Bandwidth Upgrades Agilent Business Center Ship scope per instructions Agilent sales partner Agilent service center Customer Return-to-Agilent Bandwidth Upgrade Models Process Description 3000 X-Series DSOX3BW32 100 MHz to 350 MHz, 2 ch, Service center DSOX3BW34 200 MHz to 350 MHz, 4 ch, Service center DSOX3BW12 500 MHz to 1 GHz, 2 ch, Service center DSOX3BW14 500 MHz to 1 G
Agilent Technologies Oscilloscopes Multiple form factors from 20 MHz to > 90 GHz | Industry leading specs | Powerful applications
www.agilent.com www.agilent.com/ind/3000X-Series myAgilent yAgilent www.agilent.com/find/myagilent A personalized view into the information most relevant to you. For more information on Agilent Technologies’ products, applications or services, please contact your local Agilent office. The complete list is available at: www.agilent.com/find/contactus www.axiestandard.