Sp ecifica ti on s
(at 0° to 55°C, and
derated above 40°C)
N6773A N6774A N6775A N6776A N6777A
DC utput ratings
Voltage 20 V 35 V 60 V 100 V 150 V
Current
1
15 A
2
8.5 A 5 A 3 A 2 A
Power 300 W 300 W 300 W 300 W 300 W
Programming accuracy:
(at 25°C ±5°C after 30 minute warm-up. Applies from minimum to maximum programming range)
Voltage 0.1% + 20 mV 35 mV 60 mV 100 mV 150 mV
Current 0.15% + 60 mA 60 mA 60 mA 30 mA 30 mA
Voltmeter/ammeter measurement accuracy:
(at 25°C ±5°C)
Voltage 0.1% + 20 mV 35 mV 60 mV 100 mV 150 mV
Current 0.15% + 15 mA 12 mA 12 mA 6 mA 6 mA
Output ripple an noise (PARD):
(from 20 Hz tp 20 MHz))
CV peak-to-peak 20 mV 22 mV 35 mV 45 mV 68 mV
CV rms 3 mV 5 mV 9 mV 18 mV 27 mV
Load effect (Regulation):
(Applies for any output load change, with a maximum load-lead drop of 1 V/lead.
The load lead drop reduces the maximum available voltage at the load.)
Voltage 13 mV 16 mV 24 mV 45 mV 68 mV
Current 6 mA 6 mA 6 mA 6 mA 6 mA
Source effect (Regulation)
Voltage 2 mV 4 mV 6 mV 10 mV 15 mV
Current 1 mA 1 mA 1 mA 1 mA 1 mA
Load transient recovery time:
(Time to recover to within the settling band following a load change from 50% to 100% and from
100% to 50% of full load.)
Voltage settling time ±0.3 V
3
±0.3 V
3
±0.5 V ±1.0 V ±2.0 V
Time <250 µs <250 µs <250 µs <250 µs <250 µs
Supplemental Characteristics (Non-warranted characteristics determined by design
that are useful in applying the product)
Programming ranges
Voltage 30 mV - 40 mV - 70 mV - 100 mV - 145 mV -
20.4 V 35.7 V 61.2 V 102 V 153 V
Current 30 mA - 15 mA - 7.5 mA - 4.5 mA - 2.75 mA -
15.3 A 8.67 A 5.1 A 3.06 A 2.04 A
Programming resolution
Voltage 7 mV 10 mV 18 mV 28 mV 43 mV
Current 9 mA 6 mA 3 mA 1.5 mA 1 mA
Measurement resolution
Voltage 10 mV 18 mV 30 mV 50 mV 77 mV
Current 9 mA 6 mA 3 mA 1.5 mA 1 mA
1
Output current is derated 1% per °C above 40 °C.
2
When relay option 760 is installed in Model N6773A, the output current is limited to 10 A.
3
When relay option 760 or 761 is installed, the settling band is ±0.35 V.
M
ore detailed specifications at
www.agilent.com/find/N6700
High Performance DC Power Supplies speed and accuracy for test optimization
N6730/40/70 family
The Agilent N6730, N6740, and
N6770 families of DC power
modules provide programmable
voltage and current, measurement
and protection features at a very
economical price, making these
modules suitable to power the
DUT or to provide power for ATE
system resources, such as f ixture
control. The N6730/40/70 families
give you clean, reliable DC power
without advanced features, plus
gives you the added benefits of
being a part of the N6700 MPS
including small size (true 1U),
mix-and-match with other N6700
DC power modules when you need
performance along with basic DC
outputs, connectivi ty v ia LAN,
USB, and GPIB, and fast command
processi ng time of l ess than 1 ms.