Operating instructions
 Language Dictionary
42
 Returned Parameters
  < NRl > CHAN? returns number of channel presently selected.
  CHAN? MAX returns the number of channels installed in the multiple
electronic load. If none are installed, 0 is returned. For single electronic
loads CHAN? MAX returns 1. CHAN? MIN always returns 1 for
either single or multiple loads.
 Suffix
 None
 Related Commands
 None
 Alternate Syntax
 INSTrument can be used as an alias for CHANnel.
CURRent Subsystem  Channel-Specific Current Programming Function
 Description
 This subsystem programs the CC (constant-current mode) function of a single electronic
load or a single channel of a multiple electronic load.
 Keywords
 Command
 CURRent[:LEVel][:IMMediate]
 CURRent[:LEVel] :TRIGgered
  Function
 Specify the input current level for the CURRent mode.
 Preset a new input current level to be valid when a trigger occurs.
 CURRent:PROTection[:LEVel]
 Set current limit at which protection occurs.
 CURRent:PROTection:DELay
 Set time for which protection current limit may be exceeded.
 CURRent:PROTection:STATe  OFF|0
 Disable protection function.
 CURRent:PROTection:STATe  ON|1
 Enable protection function.
 CURRent:RANGe
 Specify full-scale input current range.
 CURRent:SLEW
 Specify the current level rate of change for all current ranges and for the
middle and maximum resistance ranges.
 CURRent:TLEVel  Specify input current level used with the TRANsient Subsystem.
 Related Subsystems
 RESistance  VOLTage










