Operating instructions
Language Dictionary
67
 PULSe A one-shot pulse that alternates between LEVel and TLEVel upon 
occurrence of an explicit trigger.
 TOGGle Each explicit trigger causes the input to alternate between LEVel and 
TLEVel.
 The input levels (LEVel and TLEVel) are programmed from the Current, Resistance, or
Voltage Subsystems. So is SLEW, which determines the rate at which the input changes
from one level to the other.
 Note
 For a detailed description of transient subsystem operation, see  Operation Overview in the
Electronic Load Operating Manual.
 Keywords
 Command
  TRANsient[:STATe] ON|1
 Function
 Enable Transient function.
  TRANsient[:STATe] OFF|0
 Disable Transient function.
  TRANsient:MODE
  CONTinuous
 Select continuous pulse train varying between LEVel and TLEVel at
FREQuency.
  TRANsient:MODE PULSe
 Select single triggered pubes of duration TWIDth.
  TRANsient:MODE TOGGle
 Select pulses that switch between LEVel and TLEVel on alternate triggers.
  TRANsient:DCYCle
 Set pulse duty cycle of CONTinuous mode.
  TRANsient:FREQuency
 Set pulse frequency of CONTinuous mode.
  TRANsient:TWIDth
 Set pulse duration of PULSe mode.
 Related Commands
 LEVel  <GET> *TRG SLEW TLEVel
 Related Subsystem
 TRIGger Subsystem