User`s guide
 Language Dictionary - 8
101
 MEASure:VOLTage:LOW?
FETCh:VOLTage:LOW?
Agilent 66311B Only
 These queries return the Low level voltage of a voltage pulse waveform. The instrument first measures
the minimum and maximum data points of the pulse waveform. It then generates a histogram of the pulse
waveform using 1024 bins between the maximum and minimum data points. The bin containing the most
data points below the 50% point is the low bin. The average of all the data points in the low bin is
returned as the Low level. If no low bin contains more than 1.25% of the total number of acquired points,
then the minimum value is returned by these queries.
Query Syntax
 MEASure[:SCALar]:VOLTage:LOW?
 FETCh[:SCALar]:VOLTage:LOW?
 Parameters
 None
 Examples
 MEAS:VOLT:LOW? FETC:VOLT:LOW?
 Returned Parameters
 <NR3>
 Related Commands
 MEAS:VOLT:HIGH? CALC:REF:LOW
 MEASure:VOLTage:MAXimum?
FETCh:VOLTage:MAXimum?
Agilent 66311B Only
 These queries return the maximum output voltage.
Query Syntax
 MEASure[:SCALar]:VOLTage:MAXimum?
 FETCh[:SCALar]:VOLTage:MAXimum?
 Parameters
 None
 Examples
 MEAS:VOLT:MAX? FETC:VOLT:MAX?
 Returned Parameters
 <NR3>
 Related Commands
 MEAS:VOLT:MIN?
 MEASure:VOLTage:MINimum?
FETCh:VOLTage:MINimum?
Agilent 66311B Only
 These queries return the minimum output voltage..
Query Syntax
 MEASure[:SCALar]:VOLTage:MINimum?
 FETCh[:SCALar]:VOLTage:MINimum?
 Parameters
 None
 Examples
 MEAS:VOLT:MIN? FETC:VOLT:MIN?
 Returned Parameters
 <NR3>
 Related Commands
 MEAS:VOLT:MAX?