 Table 8-1. Subsystem Commands Syntax (continued)
 OUTPut
  [:STATe] <bool>
 Enables/disables the dc source output
  :TYPE [:CAPacitance] <setting>
 Sets output capacitor compensation (HIGH | LOW)
  :DFI
  [:STATe] <bool>
 Enables/disables the DFI output
  :SOURce <source>
 Selects event source (QUES | OPER | ESB | RQS | OFF)
  :PON
  :STATe <state>
 Set power-on state (*RST | RCL0)
  :PROTection
  :CLEar
 Reset latched protection
  :DELay <n>
 Delay after programming/before protection
  :RI
  :MODE <mode>
 Sets remote inhibit input (LATC | LIVE | OFF)
 SENSe
  :CURRent
  [:DC]
  RANGe [:UPPer] <n>
 Selects the high current measurement range
  :DETector <detector>
 Selects the current measurement detector (ACDC | DC)
  :FUNCtion <function>
 Configures the measurement sensor ("VOLT" | "CURR")
  :PROTection
  :STATe <state>
 Enables/disables open sense lead detection
  :SWEep
  :OFFSet
  :POINts <n>
 Defines the offset in the data sweep
  :POINts <n>
 Define the number of data points in a sweep
  :TINTerval <n>
 Sets the digitizer sample spacing
  :WINDow [:TYPE] <type>
 Sets the measurement window function (HANN | RECT)
 [SOURce:]
  CURRent
  [:LEVel]
  [:IMMediate][:AMPLitude] <n>
 Sets the output current level
  :TRIGgered [:AMPLitude] <n>
 Sets the triggered output current level
  :PROTection
  :STATe <bool>
 Enables/disables current limit protection
  DIGital
  :DATA [:VALue] <n>
 Sets and reads the digital control port
  :FUNCtion <function>
 Configures digital control port (RIDF | DIG)
  VOLTage
  [:LEVel]
  [:IMMediate][:AMPLitude] <n>
 Sets the dc voltage level
  :TRIGgered [:AMPLitude] <n>
 Sets the transient voltage level
  :PROTection
  [:LEVel] <n>
 Sets the overvoltage protection threshold
  :STATe <bool>
 Enables/disables overvoltage protection