Specifications
92 System Diagnostics  Chapter 5
AVERTISSEMENT Lors du dépannage, il est probable que des tensions pouvant 
causer des blessures ou la mort soient présentes. Le 
dépannage ne doit étre confié qu’à un personnel d’entretien 
qualifié.
Caution To prevent electrostatic discharge (ESD): from damaging 
sensitive system components, always wear a grounded, 
anti-static wrist strap when working on the system
Diagnostics Strategy
Two diagnostic testplans were developed for your test system at the factory. 
Dgn.tpa does not require a test fixture and performs self-tests and 
communications tests on the system instrumentation. Cedgn.tpa requires an 
optional test fixture and performs more extensive loopback testing on the 
system. Both testplans are located in:
C:\Program Files\Agilent\TS-5400 System Software\testplan\dgn
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com