Technical data
Testing Performance 3
16800 Series Portable Logic Analyzers Service Guide 35
Prepare the Logic Analyzer for Testing
1 Record the logic analyzer’s model and serial number in 
the Performance Test Record (see page 68). Record your 
work order number (if applicable) and today’s date.
2 Record the test equipment information in the “Test 
Equipment Used” section of the Performance Test Record.
3 Turn on the logic analyzer.
a Connect the keyboard to the rear panel of the logic 
analysis mainframe.
b Connect the mouse to the rear panel of the mainframe.
c Plug in the power cord to the power connector on the 
rear panel of the mainframe.
d Turn on the main power switch on the mainframe 
front panel.
While the logic analyzer is booting, observe the boot 
dialog for the following:
• Ensure all of the installed memory is recognized.
• Any error messages.
• Interrupt of the boot process with or without error 
message.
4 During initialization, check for any failures.
If an error or an interrupt occurs, refer to Chapter 5, 
“Troubleshooting,” starting on page 71.