User`s guide

Index-4
Index
renaming, 4-50
sequential CSV naming of
, 4-43
to delete all
, 4-49
filter, characteristics
, 1-72
finite impulse width (or rise time)
,
3-27
fixed IF mixer adjustments
tuned receiver mode
, 2-26
fixed IF mixer measurements
,
2-26
addressing and configuring two
sources
, 2-29
calling the next measurement
sequence
, 2-29
decrementing the loop counter
,
2-31
frequency list sweep of 26
points
, 2-28
incrementing the source
frequencies
, 2-31
initializing loop counter value to
26
, 2-29
labeling the screen
, 2-31
presetting the instrument
, 2-27
prompting user to connect mixer
test setup
, 2-28
response calibration
, 2-28
sequence 1 setup
, 2-26
sequence 2 setup
, 2-31
taking data
, 2-31
tuned receiver mode
, 2-28
fixed markers
, 1-29
fixtures
, 6-48
designing your own fixture
, 6-49
flat limit lines
, 1-77
floppy disk, what you can save
,
4-35
form feed sequence
, 4-24
sending to the printer
, 4-24
format
, 7-9
format arrays
, 7-9
format markers, polar
, 1-32
formats, analyzer display
, 7-25
formatting a disk
, 4-51
forward stepping in edit mode
,
1-108
forward transform
measurements
, 3-22
demodulating the results of the
forward transform
, 3-23
forward transform range
, 3-24
interpreting the forward
transform horizontal axis
,
3-23
interpreting the forward
transform vertical axis
, 3-22
forward transform mode
, 3-4
forward transform range
, 3-24
four-channel display
4 Param Displays softkey
, 1-18
Channel Position softkey
, 1-17
customizing
, 1-17
viewing
, 1-14
Freelance, using
, 4-21
frequency
segments, editing
, 6-34
signals, deleting
, 6-35
span, decreasing
, 5-10
span, setting
, 1-37
frequency bands
adding
, 1-89
changing
, 1-88
deleting
, 1-90
setting
, 1-87
frequency drift
, 5-5
frequency list sweep of 26 points
,
2-28
frequency offset mode operation
,
2-10
frequency offset mode, conversion
compression
, 2-39
frequency offset mode, conversion
loss
, 2-13
frequency offset operation
, 7-87
frequency range
, 1-59, 7-89
frequency range, setting
, 1-5
frequency range, setting for time
domain low pass
, 3-15
frequency response
, 7-42
frequency response and isolation
error corrections
, 6-17
reflection measurements
, 6-19
transmission measurements
,
6-17
frequency response error
corrections
, 6-12
receiver calibration
, 6-15
response error correction for
reflection measurements
,
6-12
response error correction for
transmission
measurements
, 6-14
frequency response of calibration
standards
, 6-6
electrical offset
, 6-6
fringe capacitance
, 6-7
fringe capacitance
, 6-7
full two-port calibration
, 7-57
full two-port error correction
, 6-29
G
gain
, 1-64
gain compression
measuring
, 1-60
using linear sweep
, 1-62
gating
, 3-35, 7-8
selecting gate shape
, 3-36
setting the gate
, 3-35
general
, 8-7
generating files in a loop counter
example
, 1-118
German FTZ emissions
requirements
, 8-8
gosub sequence command
, 1-109
GPIB commands
, 1-124
GPIB operation
address menu
, 7-80
GPIB STATUS indicators
, 7-80
local key
, 7-79
pass control mode
, 7-80
system controller mode
, 7-80
talker/listener mode
, 7-80
using the parallel port
, 7-81
GPIO mode
, 1-110, 7-81
graphic files
saving measurement results as
,
4-44
grids
moving marker information off
the grids
, 1-26
group delay
, 1-47
group delay format
, 7-27
group delay measurements
, 2-34
group delay principles
, 7-32
H
harmonic measurements
additional
, 1-57
making
, 1-56
harmonic operation
, 7-88
accuracy and input power
, 1-59,
7-89
coupling power between
channels 1 and 2
, 1-59, 7-89
dual-channel operation
, 1-58,
7-88
frequency range
, 1-59, 7-89
single-channel operation
, 1-58,
7-88
test setup, typical
, 7-88
understanding
, 1-58
harmonics, measuring
, 1-55
making harmonic
measurements
, 1-56
high dynamic range
measurement
, 2-23
swept RF/IF conversion loss
,
2-20
high dynamic range
measurement
, 2-23