Agilent 86100A/B Series Plug-in Modules Installation Guide
Installation Guide Installation Instructions Installation Instructions This plug-in module is designed for use with the Infiniium DCA Agilent 86100A/B wide-bandwidth oscilloscope. To install the module into the Infiniium DCA 1 Slide the module into an available front-panel slot. You can remove or install a module while the instrument is in operation. 2 Finger tighten the two knurled screws on the module’s front panel. Up to two modules can be inserted into the Infiniium DCA.
Installation Guide Installation Instructions Using an Agilent 86100A The following modules require that firmware revision A.03.04 or later be installed in the Agilent 86100A/B: 83494A, Option 103 and Option 107 86102A 86103B 86105B 86107A 86111A 86111U 86113A 86115B 86116A 86116B 86117A 86117B 86118A The firmware upgrade is enclosed in the module shipping container. Agilent recommends that you use the latest version of firmware.
Installation Guide General Safety Considerations General Safety Considerations This product has been designed and tested in accordance with IEC Publication 1010, Safety Requirements for Electronic Measuring Apparatus, and has been supplied in a safe condition. The instruction documentation contains information and warnings which must be followed by the user to ensure safe operation and to maintain the product in a safe condition. Install the plug-in module according to the enclosure protection provided.
Installation Guide General Safety Considerations CAUTION Electrical channel input circuits and the trigger input circuit can be damaged by electrostatic discharge (ESD). Therefore, avoid applying static discharges to the front-panel input connectors. Prior to connecting any coaxial cable to the connectors, momentarily short the center and outer conductors of the cable together. Avoid touching the front-panel input connectors without first touching the frame of the instrument.
Installation Guide Declaration of Conformity Declaration of Conformity 6
Installation Guide Regulatory Information Regulatory Information Radio-Frequency Electromagnetic Field Immunity - IEC 61000-4-3: 1995 passes criterion B According to IEC 61000-4-3: 1995, degradation of system noise performance may be observed in some narrow frequency ranges when a 3 V/m radio-frequency electromagnetic field is applied to the 86100A,B mainframe with an 86102U, 86106B, or 86107A module installed.
Notices © Agilent Technologies, Inc. 2000-2002 Warranty Safety Notices No part of this manual may be reproduced in any form or by any means (including electronic storage and retrieval or translation into a foreign language) without prior agreement and written consent from Agilent Technologies, Inc. as governed by United States and international copyright lays. The material contained in this document is provided “as is,” and is subject to being changed, without notice, in future editions.