Technical data

68 Agilent U7232A DisplayPort Electrical Performance Compliance Test Application
7 Source Non Pre-Emphasis Level Differential Tests
The resultants specifications are as identified below:
Measurement 1: 0.8 dB Resultant 6.0 dB
Measurement 2: 0.1 dB Resultant 5.1 dB
Measurement 3: 0.8 dB Resultant 6.0 dB
Test R ef er en ce s
See Test 3- 2: Non Pre- Emphasis Level Verification Testing, in the
DisplayPort- Compliance Test Specification Version 1.1.
Table 9 Compared Levels
Measurement Voltage
Peak-Peak_LevelA
Voltage
Peak-Peak_LevelB
1 600mV nominal (0 dB) 400mV nominal (0 dB)
2 800mV nominal (0 dB) 600mV nominal (0 dB)
3* 1200mV nominal (0 dB)* 800mV nominal (0 dB).
* if device optionally capable