If you start repetitive run, the oscilloscope acquires and displays data, 
averaging each run with the preceding set accumulated since you 
selected repetitive run. When the oscilloscope has acquired the 
number of waveforms you selected, it displays the advisory message 
"Number of averages has been met." All new data is weighed at 1/N and 
is averaged with the previous data. All data is retained.
If you set the Run mode to Single, acquisitions are not made until you 
initiate a Run. If Average # is set to 16, as in the previous example, the 
"Number of averages has been met" message will not be displayed until 
you have selected the Run field 16 times.
If you bring a waveform that is being averaged in the oscilloscope into 
the waveform display of another time correlated module, such as the 
timing analyzer, the waveform will not continue to average. Only the 
most recent acquisition, not the average trace data, will appear on the 
screen. To view an averaged mode trace with other time correlated 
waveforms, bring those other waveforms into the display of the channel 
that is setup for average mode.
Accumulate mode
In Accumulate mode, the oscilloscope accumulates all waveform 
acquisitions and displays them on the screen without erasing the 
previously acquired waveforms. This is similar to infinite persistence 
on an analog storage oscilloscope. These acquisitions will stay on the 
display until Mode is changed, or until the waveform is adjusted by a 
control that causes the display to change, such as s/Div, Delay, or 
Connect Dots from On to Off.
When in Accumulate mode, the operation of the display grid follows 
special rules when turned on or off (refer to the Grid Field paragraph 
later in this chapter).