Disk Drive Operations
Load and Store
When you choose Load or Store, you next need to set the field 
immediately to the right. This field presents at least three choices: All, 
System, and Analyzer. If you have other software loaded, it might add 
to the list of choices. 
All
Choose All to store or load both system and analyzer information. If 
you are storing, two files (one for the system and one for the analyzer) 
are created. The system file ends in "._ _" and the analyzer file ends in 
"._A".
System
System files store system configurations. System information for the 
1670G-series consists of settings for printer, controller, RS-232-C, 
GPIB, shade, and sound. LAN settings are not saved. System 
configuration files end in two underscores and have a file type of 
167x_cnfg.
Analyzer
Analyzer configuration files store measurement setups, including data. 
If you are storing the current measurement and an inverse assembler is 
already loaded, when you reload the file you are now creating it will try 
to pull in the inverse assembler. Other attributes stored in analyzer 
configuration files include labels, trigger sequence, arming 
configuration, measurement data, markers, analyzer names, and pod 
assignments. Analyzer configuration files end in "._A" and have a file 
type of 167xan_config.