User`s guide
  305
Logic Analyzer Reference
The Analyzer Format Menu
Master and Slave Clock fields (State only)
The Master and Slave Clock fields are used to construct a clocking 
arrangement. A clocking arrangement is the assignment of appropriate 
clocks, clock edges, and clock qualifier levels which allow the analyzer 
to synchronize itself on valid data.
Clock selections
When the Master or Slave Clock field is selected, a clock/qualifier 
selection menu appears showing the available clocks and qualifiers for 
a clocking arrangement. Depending on the model, there are a 
maximum of four clocks available (J through M), and a maximum of 
four clock qualifiers available (Q1 through Q4).
Clock edges are ORed to clock edges, clock qualifiers are ANDed to 
clock edges, and clock qualifiers can be either ANDed or ORed 
together. All clock and qualifier combinations on the left side of the 
graphic line are ORed to all combinations on the right side of the line. 
For example, in a six-clock model, all combinations of the J, K, and L 
clock with Q1 and Q2 qualifiers, are ORed to the clock combinations of 
the M, N, and P clocks with Q3 and Q4 qualifiers.