User`s guide
  321
Logic Analyzer Reference
The Analyzer Trigger Menu
Using the Occurrence Counters
Occurs field. When "Occurs" is selected, the < and > duration 
functions change to an occurrence counter. Use the occurrence 
counter to delay sequence evaluation until the resource term has 
occurred a designated number of times. If the "else on" branch 
becomes true before all specified occurrences of the primary "Trigger 
on" branch, the secondary "else on" branch is taken.
Using the timer
Timers are like other resource terms in that they are either true or 
false. Timers can be set to Start, Stop, Pause, or Continue as the 
analyzer enters a sequence level. The two timers are global, so each 
sequence level can control the same timer. The default timer condition 
in all sequence levels is Off.
Timers start as you enter the sequence level, and when the timer count 
expires, the timer becomes true. If a timer is paused in one level, it 
must be continued in another level before it can count through.
As more sequence levels are added, the timer status in the new levels 
defaults to Off. Timers must be continued or started in each new level 
as appropriate. When a timer expires or stops, its count resets to zero.
Branching
If either the less than or greater than duration is used, only the primary 
branch is available. Otherwise, each sequence level except for the last 
has two-way branching.
If the primary branch is taken, the analyzer goes to the next level. If the 
primary branch is not found, the analyzer immediately evaluates the 
"Else on" secondary branching term.