User`s guide
90   
Using the Trigger Menu
Managing Memory
To selectively store branch conditions 
(state only)
Besides setting up your trigger levels to store anystate, no state, or 
some subset of states, you can also choose whether or not to store 
branch conditions. Branch conditions are always stored by default, and 
can make tracing the analyzer's path through a complicated trigger 
easier. If you really need the extra memory, however, it is possible to 
not store the branch conditions.
You cannot set the analyzer to store only some branches in a trigger 
sequence specification. 
1 In the Analyzer Trigger menu, select Acquisition Control.
The Acquisition Control menu pops up. If the acquisition mode is set to 
Automatic, the menu contains a single field and an explanation. If 
Acquisition has been customized, it has 3 fields and a picture showing 
where the trigger is currently placed in memory.
2 If the mode is Automatic, select the field and toggle it to Manual.
The menu now shows three fields and a picture.
3 Select the Branches Taken Stored field.
It toggles to Branches Taken Not Stored.
4 Select Done.