User`s manual

Table 4-5. Aperture Time, Range, and Resolution Settings
Aperture Time
Integration Time (PLCs)
10 µs*
0.0005
100 µs
0.005
2.5 ms
0.125
16.7 ms
1
20 ms
1
267 ms
16
320 ms
16
DC & AC Voltage
(Using CONFigure/MEASure)
Resolution
Range
DC
Range
AC
Percent
Overrange
0.113 V
0.91 V
7.27 V
58.1 V
300 V
0.0795 V
0.63 V
5.09 V
40.7 V
300 V
10%
10%
10%
10%
0%
7.629 µV
61.035 µV
488.281 µV
3.906 mV
31.25 mV
3.814 µV
30.517 µV
244.14 µV
1.953 mV
15.625 mV
0.476 µV
3.814 µV
30.517 µV
244.14 µV
1.953 mV
0.119 µV
0.953 µV
7.629 µV
61.035 µV
488.28 µV
0.119 µV
0.953 µV
7.629 µV
61.035 µV
488.28 µV
28.9 nV
0.238 µV
1.907 µV
15.258 µV
122.07 µV
28.9 nV
0.238 µV
1.907 µV
15.258 µV
122.07 µV
DC & AC Voltage
(Using RANGe)
Resolution
Range
DC
Range
AC
Percent
Overrange
0.125 V
1.0 V
8.0 V
64.0 V
300 V
0.0875 V
0.7 V
5.6 V
44.8 V
300 V
0%
0%
0%
0%
0%
7.629 µV
61.035 µV
488.281 µV
3.906 mV
31.25 mV
3.814 µV
30.517 µV
244.14 µV
1.953 mV
15.625 mV
0.476 µV
3.814 µV
30.517 µV
244.14 µV
1.953 mV
0.119 µV
0.953 µV
7.629 µV
61.035 µV
488.28 µV
0.119 µV
0.953 µV
7.629 µV
61.035 µV
488.28 µV
28.9 nV
0.238 µV
1.907 µV
15.258 µV
122.07 µV
28.9 nV
0.238 µV
1.907 µV
15.258 µV
122.07 µV
2-Wire & 4-Wire Resistance
(Using CONFigure/MEASure)
Resolution
Range
Percent
Overrange
232
1861
14894
119156
1048576
10%
10%
10%
10%
10%
15.625 m
125 m
1
8
64
7.812 m
62.5 m
0.5
4
32
0.976 m
7.812 m
62.5 m
0.5
4
244 µΩ
1.95 m
15.6 m
125 m
1
244 µΩ
1.95 m
15.6 m
125 m
1
61 µΩ
488 µΩ
3.9 m
31.2 m
250 m
61 µΩ
488 µΩ
3.9 m
31.2 m
250 m
2-Wire & 4-Wire Resistance
(Using RANGe)
Resolution
Range
Percent
Overrange
256
2048
16384
131072
1048576
0%
0%
0%
0%
0%
15.625 m
125 m
1
8
64
7.812 m
62.5 m
0.5
4
32
0.976 m
7.812 m
62.5 m
0.5
4
244 µΩ
1.95 m
15.6 m
125 m
1
244 µΩ
1.95 m
15.6 m
125 m
1
61 µΩ
488 µΩ
3.9 m
31.2 m
250 m
61 µΩ
488 µΩ
3.9 m
31.2 m
250 m
Max. Readings/Second **
Line Frequency Rejected
Normal Mode Rejection
Bits of Resolution
13,150
---
0 dB
14
3,000
---
0 dB
15
350
400 Hz
60 dB
18
58
60 Hz
60 dB
20
49
50/400 Hz
60 dB
20
2
60 Hz
84 dB
22
1.9
50/400 Hz
84 dB
22
* 10 µs aperture time is only available when a fixed range is specified.
** Reading rates are approximate and are achieved using a stand-alone multimeter, DC voltage function, fixed range,
autozero off, offset compensation off, reading stored in mainframe/command module memory. See Table 4-6 on
page 110 for the necessary sample rates.
92 Understanding the HP E1326B/E1411B Multimeter Chapter 4