Specifications

39
ring. Multiple receiver configurations can also be achieved by use of the E6473A direct
connect hub (see E6473A direct connect hub product overview, literature number 5988-
3176EN, for further details).
Each receiver option includes:
RF antenna for the corresponding frequency band
Cable to connect to other receivers
Cable to connect to PC
Kit for mounting receiver in a vehicle
AC/DC power supply
Cigarette lighter power cord
GPS antenna with cable
Agilent digital RF receiver specifications
Agilent E6450C, E6452C, E6453C, E6455C and E6457C
Frequency
Frequency range
1
E6452C 824-849 MHz [819 – 854]
869-894 MHz [864 – 899]
E6450C 1850-1910 MHz [1845 – 1915]
1930-1990 MHz [1925 – 1995]
E6455C
1
1920-1980 MHz [1895 – 1990]
2110-2170 MHz [2100 – 2180]
E6457C 832-870 MHz [827 – 875]
887-925 MHz [882 – 930]
E6453A
1
710-1785 MHz [1705 – 1790]
1805-1880 MHz [1800 – 1885]
Frequency accuracy
± 1 ppm with GPS time synchronization
± 0.05 ppm characteristic
IF bandwidth
2
30 kHz characteristic
200 kHz characteristic (options #390, #391 only)
1. Spectrum measurement allows tuning ±10 MHz above and below specified frequency ranges. In addition,
for the IMT-2000 band receiver (option #360 and #361), the PHS band is also covered (down to
1895MHz). These extended ranges are shown in brackets – [ ]. The performance is not specified in these
extended ranges. Characteristic noise floor increase is 2 dB ±10 MHz. For the IMT-2000 band receiver, at
–25MHz with respect to specified range, the characteristic noise floor increase is 5dB. Characteristic
amplitude accuracy is unchanged with respect to specified range.