User`s guide

Base Station Emulator Mode 3
E6651A User’s Guide 45
Power Control Test
The Power Control Test function implemented in the E6651A
Test Set operates through MAC messages between the BS
and SS. All the power control algorithms specified in
IEEE802.16 are supported in the E6651A.
Power Control modes supported in E6651A
E6651A supports close loop and open loop mode which are
the SS power control mode.
Power control parameters supported in E6651A
Closed Loop - Adjust the Power Adjust value.
Open Loop - Adjust the OffsetBSperSS and NI (UL noise
and interference level IE) value.
The E6651A Power Control menu has three sub menus:
Figure 20 Power Control menu screen
Setting - Use to configure the power control
parameters.
•Test Mode - Use to configure the power control
mode (algorithm).
Send Message - Use to send the MAC
message for the selected test mode to the SS.
Setting
Test Mode
Send Message