Technical data
Chapter 7 201
CDMA Analyzer
Optional CDMA Tx Analyzer Measurement Settings
CDMA Analyzer
limits are set in dBm. Any measured pilot power value that is above or below the
set limits will result in a failure indication.
• Delta Page Power Limits: Sets the upper and lower limits of the delta page
power. The limits are set in dB and are relative to the pilot power. Any measured
delta page power value that is above or below the set limit will result in a failure
indication.
• Delta Sync Power Limits: Sets the upper and lower limit of the delta sync
power. The limit is set in dB and is relative to the pilot power. Any measured
Delta Sync Power value above or below the set limit will result in a failure
indication.
Setting the Measurement Frequency Error Limits
Step Notes
1 [Setup]
2 [Limits]
3 On [Freq Error Limits]
select
On or Off.
Enables you to toggle the measurement limits
function On (active) and Off (inactive).
• If set to
On, the Frequency Error will change
from black to red (fail) or green (pass) and
indicate either a “P” (pass) or “F” (fail). If the
measured value exceeds either the upper or
lower limit, the words ALL PASS in the bar at
the bottom of the screen, will change to
FAILURE.
•If set to
Off, the channel freq/number value will
be displayed in blue. The area at the bottom of
the screen that is used to indicate Pass or Fail
will be over-written. The bar at the bottom of
the screen, will indicate measurement in
progress.