Technical data
Chapter 7 217
CDMA Analyzer
Interpretation of CDMA Tx Analyzer Measurement Results
CDMA Analyzer
Delta Quick Page Channel Power
If the measured value of Delta QPCH Power is more than +/-0.5 dB different from
the intended setting, it may indicate that the digital gain setting for the QPCH has
been changed.