Technical data
288 Chapter 10
Distance to Fault
Measuring Distance to Fault
Distance to Fault
9 Using the numeric
keypad, enter the stop
distance for the part of
the cable that you wish
to zoom in on.
The greatest accuracy is obtained when you enter a
cable length slightly greater than the cable length
being tested. If you are not sure of the cable length,
enter a value 1.25 times the estimated length, and
enter a start distance value of 0 m (0 ft) as
described in Step 6. Depending on the return loss of
the antenna or device at the end of the cable, you
may see a high relative mismatch displayed at the
actual length of the cable
10 [Cable Type]
11 On [Cable Type] on the
right, select
RG, BTS,
or
Cust.
Each time you press this softkey, the selected
option changes. If you select
RG or BTS, you will
be asked to select from a list of common cable
types, the specific type of cable you are measuring
[Select Cable].
If the type of cable you are measuring is not listed,
you need to select
Cust (Custom Cable). Proceed
to Step 14 for custom cable selection.
12 Press [Select Cable] to
display a predefined list
of RG and BTS cables.
Use the knob, or the up and down arrow keys, to
scroll through the list and to highlight your chosen
cable.
13 [Select] The type of cable you selected will be displayed at
the upper left of the screen. Now proceed to Step
15.
Step Notes