Technical data
358 Chapter 12
GSM and EDGE Analyzer
Optional GSM and EDGE Tx Analyzer Measurement Settings
GSM and EDGE Analyzer
To Set the Channel Scan Upper and Lower Limits:
Setting Frequency Error Limits
You can set upper and lower Frequency Error Limits for your Frequency Error
Measurement results.
If Freq Error Limits are turned On, and your measured frequency error is within the
limits you have specified, the numeric result reported in the metrics portion of the
screen will be displayed in green, and the Limit Pass will be indicated by “(P)” after
the result. If your measured frequency error is outside your specified limits, the
numeric result reported in the metrics portion of the screen will be displayed in red,
and the Limit Failure will be indicated by “(F)” after the result.
To Set the Frequency Error Upper and Lower Limits:
Step Notes
1 [Setup]
2 [Chan Scan Pwr Limits]
3 [Limits]
4 [On] or [Off]
5 Set the upper limit.
a. [High Limit]
b. Enter the number on
the numeric keypad.
c. [dBm]
The limit is specified in dBm.
6 Set the lower limit.
a. [Low Limit]
b. Enter the number on
the numeric keypad.
c. [dBm]
The limit is specified in dBm.
Step Notes
1 [Setup]