Performing a Basic 1xEVDO Transmitter Measurement
1xEV-DO Analyzer and Over Air
Test
Performing a Basic 1xEVDO Transmitter Measurement
Once you have taken the access network out of service (this is necessary, for
example, when you are setting the Tx Power Out level) and you have made the
proper connections, you can perform 1xEVDO transmitter measurements.
Step Notes
1.
Mode If your test analyzer is already performing a
1xEV-DO Over the Air measurement, you can
switch quickly to 1xEV-DO Transmitter
measurements by pressing [Display] and then
switching OTA PN Scanner Off. If you do this,
you can omit steps 2 and 3, and skip straight to
Step 4.
2. [Tx Analyzer] See above.
3. [1xEV-DO Anl] See above.
4. [Chan Std]
5. Highlight the channel
standard you want using the
up and down arrow buttons.
6. [Select]
7. On [Units] select
Chan or
Freq.
Each time you press this softkey, the selected
option changes.
8. Enter the channel or
frequency using the numeric
keypad.
9. [Fwd] Selects the forward 1xEV-DO channel.
10. [Fr/Time Ref]
11. [GPS] or [External Even Sec] If the sky (and hence the satellites) is not
visible from the position of your analyzer, use
External Even Sec as the time reference.