Specifications
16
Accessories
□ Rack mount kit without handles (Option 1CM) 
  Adds a rack mount (5063-9217) and rail kit (E3663AC) for use 
 without handles.
□ Rack mount kit with handles (Option 1CP)
  Adds a rack mount (5063-9237)
2
 and rail kit (E3663AC) for use 
  with standard supplied handles.
Configuration Details
Selecting the correct mixer-test configuration:
Most mixer or converter test applications require Options 014, 080, 
and 082 for conversion loss/gain, or Options 014, 080, 081 and 
083 for conversion loss/gain and phase/delay measurements. If 
you want to create and automate your own custom frequency-
offset measurements (for example, intermodulation distortion), 
you may only need Options 014 and 080. For converters that 
require input power below -27 dBm, or for devices that have a 
large amount of LO feedthrough (like an unfi ltered mixer), Option 
UNL, which adds source attenuators, is highly recommended. 
Besides allowing lower input power levels, these attenuators 
improve the isolation between the PNA’s internal source and 
LO leakage signals, helping to prevent source-unleveled errors. 
For devices that put out signals near or above the receiver’s 
compression levels (which varies between –3 and +5 dBm, 
depending on the model and frequency), Option 016 is recom-
mended, which adds receiver attenuators. Finally, Option 010, 
which adds time-domain analysis, is very useful for gating out 
unwanted, time-delayed responses which often occur when 
measuring mixers. 
PNA Series Network Analyzer
□ 4-port measurement application (Option 550)
1
  Adds multiport analyzer mode to any PNA network analyzer 
  with Option 014 configurable test set, which enables full 
  4-port error correction and measurement capabilities using an 
  external test set. Only standard measurement class is available 
  in the multiport analyzer mode.
□ N-port capabilities (Option 551)
1
  Adds multiport analyzer mode to any PNA network analyzer 
  with Option 014 configurable test set, which enables full 
  N-port error correction and measurement capabilities using 
  an external test set. Only standard measurement class is 
  available in the multiport analyzer mode.
Pulse, antenna, mm-wave
□ Pulsed-RF measurement capability (Option H08)
1 
Provides software to set up and control pulsed-RF measurements 
  with point-in-pulse capability. The software sets the coefficient 
  of the PNA’s digital-IF filter to null out unwanted spectral 
  components, enables the IF gates provided with IF access 
  (Option H11), and controls selected Agilent pulse generators. 
  It can be run on the PNA or an external computer. A “.dll” file 
  containing the IF-filter algorithms is included for automated 
 pulsed-RF testing. The pulsed application is configured to work 
  with the Agilent 81110A series pulse generator. 
  For more detailed information regarding pulsed measurement 
  capabilities with the microwave PNA refer to the Agilent Web 
 site www.agilent.com/find/pna and download the PNA Series 
  MW Network Analyzers Configuration Guide for Pulsed   
 Measurements, literature number 5989-7913EN. 
□ IF access (Option H11) 
  Provides hardware to enable antenna, point-in pulse, and 
  broadband millimeter-wave measurements to 110 GHz. For 
  each of the MW PNA’s measurement receivers, IF gates 
  (enabled with pulsed measurement capability, Option H08) and 
  external IF inputs are added. In addition, access to the PNA’s 
  internal RF and LO source is provided for remote mixing 
  applications. For basic antenna measurements, only Option H11 
  is necessary. Pulsed antenna applications also require the 
  pulsed measurement capability (Option H08). Broadband   
  measurements to 110 GHz, also requires an N5260A   
  millimeter-wave test set controller. 
  Note: Use external IF access for up to 20 dB more sensitivity 
  when making antenna measurements with a remote mixing 
  configuration. Add Option H08 (Pulsed-RF Measurement  
  Capability) to enable advanced pulsed measurements. Or 
  upgrade to a broadband (10 MHz to 110 GHz) VNA system 
  simply by purchasing an N5260A controller test set with test 
  heads (Option 110, 120, or 130).
1.  Up to 67 GHz.
2.  The 5063-9237 kit assumes you have the standard handles shipped 
  with the instrument. If you do not have handles, order a 5063-9224 kit.  