Specifications
8
Measurement applications
□ Time domain (Option 010)
  This option enables the PNA-X to view reflection and   
  transmission responses in time or distance. Use time domain 
  to tune filters, gate out the response of fixtures and cables, 
  characterize the impedance of transmission lines and more.
□ Frequency offset (Option 080)
  This option enables the PNA-X to set the source frequency 
  independently from where the receivers are tuned. This ability 
  is important for measuring amplifiers, mixers, and frequency 
 converters.
□ Scalar-calibrated converter measurements (Option 082)
  With a simple setup and calibration, this application delivers 
  the highest accuracy for scalar conversion-loss/gain measure- 
  ments by combining one-port and power-meter calibrations to 
  remove mismatch errors. Option 082 provides an intuitive and 
  easy-to-use user interface for setting up mixer and converter 
  measurements, with single or dual conversion stages. It can 
  control the PNA-X’s built-in second source as well as external 
  signal generators for use as LO signals. Supported external 
  sources include the Agilent ESG, PSG, and MXG series, as 
  well as other SCPI-controlled signal generators. Option 082 
  requires Option 080, and cannot be ordered with Option 083. 
  It is compatible with Option 084, which enables measurements 
  of converters with internal LOs.
□ Vector- and scalar-calibrated converter measurements (Option 083)
  This application includes the new scalar mixer/converter + 
  phase measurement class which provides fully calibrated con 
  version gain/loss, relative phase, and absolute group delay 
  measurements of mixers and converters without the need for 
  a reference mixer. A vector mixer/converter measurement 
  class is also included for measurements with the least   
  amount of trace noise for phase/delay measurements. Option 
  083 provides an intuitive and easy-to-use user interface for 
  setting up mixer and converter measurements, with single or 
  dual conversion stages. It can control the PNA-X’s built-in 
  second source as well as external signal generators for use as 
  LO signals. Supported external sources include the Agilent 
  ESG, PSG, and MXG series, as well as other SCPI-controlled 
  signal generators. Option 083 requires Option 080, and cannot 
  be ordered with Option 082. It is compatible with Option 084, 
  which enables measurements of converters with internal LOs.
□ Embedded LO measurements (Option 084)
  This option tunes the PNA-X receivers to the output frequency 
  of the converter under test, without the need for access to 
  internal LOs or a common reference signal. For converters 
  with embedded LOs, this option enables measurements of 
  match-corrected conversion loss/gain (requires Option 082 or 083), 
  absolute group delay (requires Option 083), intermodulation dis- 
  tortion (requires Option 087), and noise figure (requires Option 028, 
  029, or H29).
□ Gain compression application (Option 086)
  The Gain Compression Application (GCA) provides input power, 
  output power, gain, and phase at an amplifier's compression 
  point, over a specified frequency and power range. GCA's   
  SMART Sweep is very fast and easy-to-use. GCA also includes 
  a guided calibration that corrects for absolute power levels, 
  frequency response, and mismatch errors.
□ Intermodulation distortion application (Option 087)
  The intermodulation distortion (IMD) application makes it very
  easy to set up and calibrate swept-IMD measurements of
  both amplifiers and frequency converters. It uses the built-in
  second source and internal combiner of the PNA-X (requires
  Option 224 or 423). The user can sweep either the center
  frequency of the two stimulus signals, the frequency spacing
  of the two stimulus signals about a fixed center frequency, or
  the power of one or both stimulus signals or the power of the
  LO signal. The analyzer can measure intermodulation distortion
  products of order 2, 3, 5, 7, or 9, and can display the associated
  intercept points. In addition, an IM Spectrum mode gives a
  spectrum-analyzer-like display for confirming or trouble-shooting
  measurements. Requires firmware A.08.33 and above.
□ Integrated true-mode stimulus application (Option 460)
  Integrated true-mode stimulus application (iTMSA) provides
  mismatch-corrected true-mode (true differential and true 
  common) stimulus and enables accurate balanced measure- 
  ments under real operating conditions. iTMSA also provides 
  balanced measurements with forward-only sweep, reverse-only 
  sweep, and frequency or power sweep with arbitrary phase 
  and amplitude offsets. Requires firmware A.08.20 and above.
□ N-port capabilities (Option 551)
1
  Adds a multiport analyzer mode to the PNA-X network analyzer, 
  that enables full N-port error correction and measurement  
  capabilities using an external test set. Only standard measure- 
  ment class is available in the multiport analyzer mode.
1.  When configured as a multiport analyzer using Option 551 and a multi- 
  port test set, the combiner feature of Option 224 or 423 is temporarily 
  disabled. When configured as a standalone analyzer, the combiner 
  feature is enabled. When ordering a test set, select a test set option 
  to specify an appropriate interconnect jumper cable set between the 
  analyzer and the test set.
PNA-X Series Network Analyzer