Specifications
9
PNA-X Series Network Analyzer
Measurement applications (continued)
□ Noise figure measurements using standard receivers (Option 028)
  This option adds firmware for high-accuracy noise figure measure- 
  ments of amplifiers, frequency converters, and mixers using the  
  PNA-X’s standard receivers, and utilizing Agilent’s unique source-
  correction technique. Using the PNA-X and an Agilent ECal module 
  configured as an impedance tuner, the effects of imperfect system 
  source match are removed, greatly improving the accuracy of the 
  cold-source technique. This approach surpasses the accuracy pro-
  vided by the Y-factor method. For fully corrected noise figure mea- 
  surements, this option requires an ECal module (m-f recommended) 
  and a power meter (both must be ordered or supplied separately). A 
  scalar calibration choice is also available that offers less accuracy, 
  but is faster and does not require the ECal module used as an   
  impedance tuner. The power meter is only used during calibration of 
  the analyzer. During calibration of the analyzer, an additional ECal or 
  mechanical calibration kit is required (also must be ordered or sup- 
  plied separately). To use a m-f ECal module as a tuner (N4691B/
  93A-M0F), Option 028 includes a semi-rigid cable (3.5 mm N5242- 
  20137 for N5241/42A or 2.4 mm N5245-20140 for N5244/45A) and 
  a m-f adapter (3.5 mm 85052-60013 for N5241/42A or 2.4 mm   
  85056-60007 for N5244/45A). For use with f-f ECal modules   
  (N4691B/93A-00F), order a m-m adapter (3.5 mm 85052-60014 or 
  2.4 mm 85056-60005). No external preamplifier is required for 
  devices with 30 dB or more of excess noise (gain plus noise figure). 
  Front panel jumpers provide a convenient spot for adding a pre-  
  amplifier and filter(s) for low gain, low noise figure devices.
□ Fully-corrected noise figure measurements (Option 029)
  This option adds high-sensitivity noise receivers and firmware 
  for high-accuracy noise figure measurements of amplifiers, 
  frequency converters, and mixers, utilizing Agilent’s unique 
  source-correction technique. Using the PNA-X and an Agilent 
  ECal module configured as an impedance tuner, the effects of 
  imperfect system-source match are removed, greatly improv 
  ing the accuracy of the cold-source technique. This approach- 
  surpasses the accuracy provided by the Y-factor method. For 
  fully corrected noise figure measurements, this option requires 
  a 3.5 mm N4691B ECal module (m-f recommended) and a  
  346C noise source (both must be ordered or supplied sepa- 
  rately). A scalar calibration choice is also available that offers 
  less accuracy, but is faster and does not require the ECal mod- 
  ule used as an impedance tuner. For measurements of mixers 
  and converters, a power meter is also required. The noise 
  source and power meters are only used during calibration of 
  the analyzer. During calibration of the analyzer, an additional 
  ECal or mechanical calibration kit is required (also must be 
  ordered or supplied separately). To use a 3.5 mm m-f ECal 
  module as a tuner (N4691B-M0F), Option 029 includes a 
  3.5 mm semi-rigid cable (N5242-20137) and 3.5 mm m-f 
  adapter (85052-60013). For use with 3.5 mm f-f ECal modules 
  (N4691B-00F), order a 3.5 mm m-m adapter (85052-60014). 
  Option 029 also allows noise figure measurements using the 
  standard receivers for high-gain (> 60 dB) devices that might 
  otherwise overload the noise receivers.
□ Add 26.5 GHz noise receivers (Option H29)
  This option adds 26.5 GHz high-sensitivity noise receivers to 
  N5244A 43.5 GHz and N5245A 50 GHz PNA-X models. The 
  option also enables use of the standard receivers for noise 
  figure measurements up to 43.5 or 50 GHz. Both receiver 
  choices yield high-accuracy noise figure measurements of 
  amplifiers, frequency converters and mixers, utilizing Agilent’s 
  unique source-correction technique. Using the PNA-X and an 
  Agilent ECal module configured as an impedance tuner, the 
  effects of imperfect system-source match are removed, greatly 
  improving the accuracy of the cold-source technique. This 
  approach surpasses the accuracy provided by the Y-factor 
  method. For fully corrected noise figure measurements, this 
  option requires an ECal module (2.4 mm N4693A m-f recom- 
  mended) and a 346C noise source (both must be ordered or 
  supplied separately). A scalar calibration choice is also available 
  that offers less accuracy, but is faster and does not require the 
  ECal module used as an impedance tuner. For measurements of 
  mixers and converters, a power meter is also required. The 
  noise source and power meter are only used during calibration 
  of the analyzer. During calibration of the analyzer, an additional 
  ECal or mechanical calibration kit is required (also must be 
  ordered or supplied separately). To use a 2.4 mm m-f ECal 
  module as a tuner (N4693A-M0F), Option H29 includes a 2.4 mm 
  semi-rigid cable (N5245-20140) and 2.4 mm m-f adapter (85056- 
  60007). For use with f-f ECal modules (N4693A-00F), order a 
  2.4 mm m-m adapter (85056-60005). For use with 3.5 mm m-f 
  ECal modules (N4691B-M0F), order two 2.4 mm to 3.5 mm m-f 
  adapters (11901C), plus a 3.5 mm semi-rigid cable (N5242- 
  20137) and a 3.5 mm m-f adapter (85052-60013). For use with 
  3.5 mm f-f ECal modules (N4691B-00F), order two 2.4 mm to 
  3.5 mm m-f adapters (11901C), plus a 3.5 mm semi-rigid cable 
  (N5242-20137) and a 3.5 mm m-m adapter (85052-60014).
Test port 1
R1
Test port 2
R2
A
B
Source 2 
Output 1
Source 2 
Output 2
rear panel
Noise receivers
10 MHz 
-
3 GHz
3 -
26.5 
GHz
Source 1
OUT 1 OUT 2
Source 2
OUT 1 OUT 2
J9J10J11 J8 J7 J2 J1