User`s guide

398 Chapter 15
W-CDMA Uplink Digital Modulation for Receiver Test
Overload Testing with Multiple PRACHs—Multiple ESGs
Overload Testing with Multiple PRACHs—Multiple ESGs
With the advanced feature of transmitting multiple PRACHs, you can perform base
transceiver station overloading using two ESGs. This gives you the capability of transmitting
up to 16 UEs. When the Frame Sync Trigger signal is used for both ESGs, they will
synchronize to within one chip of the base station frame synchronization signal. When ESG 2
is synchronized using the ESG Sync Pulse signal, you may experience an additional half chip
delay from ESG 2. Figure 15-34 shows the multiple ESG setup and Table 15-2 list the signals
shown in the drawing and their respective ESG rear panel connections.
Figure 15-34 Multiple ESG Setup