Specifications

Programming Guide 4-27
ESG Family Signal Generators Softkey/Command Cross-Reference
Agilent 8656/57-Compatible Language
S3 (Internal 1 kHz Modulation Source)
If AM1 is on, this command is mapped to:
[:SOURce]:AM[1]:INTernal[1]:FREQuency 1 kHz
If FM1 is on, this command is mapped to:
[:SOURce]:FM[1]:INTernal[1]:FREQuency 1 kHz
S4 (Modulation Source Off)
If the last active function was PM, (other than any modulation source commands), pulse
modulation is disabled by mapping to the following command:
[:SOURce]:PULM:STATe OFF
If the last command was S2 or S3, internal modulation is turned off for whatever
modulation type is currently active by mapping to the following commands:
[:SOURce]:AM[1]:STATe OFF
[:SOURce]:FM[1]:STATe OFF
The S2 or S3 condition is also discarded so that the next time S4 is sent, the entire
modulation type will be turned off.
If the last command was S1, external modulation is turned off for whatever modulation
type is currently active by mapping to the following commands:
[:SOURce]:AM2:STATe OFF
[:SOURce]:FM2:STATe OFF
The S1 condition is also discarded so that the next time S4 is sent, the entire
modulation type will be turned off.
If the last active function was AM or FM, the entire appropriate modulation type is
turned off by mapping to the following commands:
[:SOURce]:AM[1]:STATe OFF
[:SOURce]:AM2:STATe OFF
[:SOURce]:FM[1]:STATe OFF
[:SOURce]:FM2:STATe OFF