262 Agilent X-Series Signal Generators User’s Guide 
Digital Signal Interface Module (Option 003/004) 
Clock Timing 
Clock Timing for Parallel Interleaved Data
The N5102A module provides the capability to interleave the digital I and Q samples. There are two 
choices for interleaving:
• IQ, where the I sample is transmitted first
• QI, where the Q sample is transmitted first
When parallel interleaved is selected, all samples are transmitted on the I data lines. This effectively 
transmits the same number of samples during a sample period on half the number of data lines as 
compared to non- interleaved samples. (A sample period consists of an I and Q sample.) Clocks per 
sample is still a valid parameter for parallel interleaved transmissions and creates a reduction in the 
sample rate relative to the clock rate. The clocks per sample selection is the ratio of the reduction. 
Figure 10- 5 shows each of the clocks per sample selections, for a parallel IQ interleaved port 
configuration, using a word sized of four bits and the clock timing relative to the I and Q samples. 
For a parallel QI interleaved port configuration, just reverse the I and Q sample positions. For input 
mode, the clocks per sample setting is always one.
Figure 10-5 Clock Timing for a Parallel IQ Interleaved Port Configuration
Q sample 
4 bits per word 
I sample 
4 bits per word 
1 Sample Period
1 Clock Per Sample
1 Clock
The I sample is transmitted on one clock transition and the Q sample is transmitted on the
Clock
other transition; the sample and clock rates are the same.