Specifications
5-21
System Command Reference Section
Pattern Generator SUBRATE CLOCK OUT
Pattern Generator SUBRATE CLOCK OUT
In this section the SOURCE5:VOLT and OUTPUT5 commands control the electrical
levels at the SUBRATE CLOCK OUT port. Refer to the previous section on page 5-20 for
SOURCE4:VOLT and OUTPUT4 commands which control the subrate PARALLEL
DATA OUTPUT ports.
NOTE See Handling Coupled Parameters,page2-11.
SOURce5:VOLTage[:LEVel][:IMMediate][:AMPLitude] <numeric
value>
Sets the peak to peak value of the subrate clock, in units of volts.
The *RST selection is 500 mV.
SOURce5:VOLTage[:LEVel][:IMMediate]:HIGH <numeric value>
This is used to set the dc high output level, in units of volts.
The *RST selection is 0 V.
SOURce5:VOLTage:ECL
Sets the output AMPLitude and HIGH values to those used for the ECL family. There is
no query form for this command.
OUTPut5:TERMination <numeric value>
Permits the subrate clock output termination level to be set to 0 V or −2V.
The *RST selection is 0 V.
OUTPut5:COUPling AC|DC
Sets the subrate clock coupling to ac or dc.
The *RST selection is dc 0 V.