Agilent Ininiium 9000 Series Oscilloscopes Data Sheet Engineered for broadest measurement capability
If you haven’t purchased an Agilent scope lately, why should you consider one now? If you’re like most engineers, you never know what your next project will demand from you. You need an oscilloscope that can adapt to a wide variety of debug and test challenges. That’s why we designed our new Ininiium 9000 Series oscilloscope to meet a full range of needs. There is no better way to experience the superiority of the Infiniium 9000 Series scopes than to see it. Contact Agilent today to request an evaluation.
What makes the Infiniium 9000 Series the go-to scope for a whole range of test and debug challenges? It’s three instruments in one 1. Scope: The powerful features of our Ininiium Series oscilloscopes coupled with superior speciications give you precise signal representation. 2. Logic analyzer: Fast deep-memory digital channels let you see critical data values and timing relationships. 3. Protocol analyzer: The world’s irst scope-based protocol viewer with multi-tab viewing.
It’s three instruments in one 1. Oscilloscope High-performance scope channels ensure superior viewing of signals under test. All models incorporate a powerful, feature-packed Infiniium oscilloscope with responsive deep memory. Up to 4 GHz bandwidth and 20 GSa/s high sample rates guarantee you’ll see a precise representation of the analog characteristics of signals you’re testing. Mask tests, histograms and a wide variety of functions such as the gated FFTs in the above image provide deep signal analysis.
It’s three instruments in one 2. Logic analyzer MSO models add 16 high-speed timing channels with standard 128 Mpts digital memory, allowing you to retain fast 2 GSa/s sample rates over long periods of time. Use the timing channels to evaluate control signal relationships and data buses up to 16 bits wide. Use symbols to more quickly interpret waveforms. Digital and mixed-signal trigger Trigger on and display individual signals or buses.
It’s three instruments in one 3. Protocol analyzer Does your design include a serial bus that is a key point for testing or debugging? Add protocol analysis capability to your scope for: • CAN • FlexRay • I2C • JTAG • LIN • MIPI D-Phy • PCle • RS-232/UART • SATA • SPI • USB • 8B/10B • digRF • SVID Quickly move between physical and protocol layer information using the time-correlated tracking marker.
Widest range of debug and compliance software applications: serial protocol-level I2C/SPI serial trigger and decode (N5391B-1NL* or Option 007 on new scope purchases) This application displays real-time time-aligned decode of I2C and SPI serial buses. Hardware-based triggering means triggering reliably, even on the most infrequent events. This application works on all models and can use any combination of scope or logic acquisition channels. For more information: www.agilent.
Widest range of debug and compliance software applications: serial protocol and FPGA USB serial trigger and protocol viewer (N5464-1NL* or Option 005 on new scope purchases) Trigger on and quickly view USB packets, payload, header and detail information. Powerful time-correlated views of waveform and symbol, to the bit level, make it easy to isolate communication faults to logic or analog sources. USB hardware-based triggering means triggering reliably, even on the most infrequent events.
Widest range of debug and compliance software applications: serial physical-layer USB 2.0 compliance testing (N5416B-1NL* or Option 029 on new scope purchases) Quickly determine USB compliance with this USB-IF recognized solution. A setup wizard guides you through test selection and coniguration. This application is USB-IF approved and supported on all 2.5 GHz and 4 GHz models. For more information: www.agilent.com/find/9000_USB-compliance Check for USB compliance.
Widest range of debug and compliance software applications: InfiniiScan and jitter analysis InfiniiScan event identification (N5415B-1NL* or Option 009 on new scope purchases) Rapidly trigger on complex events and identify signal integrity issues. This innovative software quickly scans through thousands of acquired waveform cycles and isolates anomalous signal behavior. Up to eight zones across channels are available. This application is supported on all models. For more information: www.agilent.
Widest range of debug and compliance software applications: viewing and analysis High-speed serial data analysis software (N5384A-1NL* or Option 003 on new scope purchases) Quickly validate signal integrity for high-speed serial interfaces with embedded clocks. Recover embedded clocks synchronized with the analog waveform view. Build and validate eye diagrams. The SDA package also includes software-based bit-level triggering and decode for 8B/10B. This application is supported on all models.
Infiniium 9000 Series applications and upgrades User-definable application (N5467C-1NL*) Rapidly develop your own automated measurements and tests. This application provides the framework you need to quickly program and automate any single or set of measurements the oscilloscope can make. The application also provides full control of other Agilent instruments and HTML reporting capabilities. For more information: www.agilent.com/find/9000_UDA Quickly automate oscilloscope measurements.
Agilent Infiniium portfolio Agilent’s real-time Infiniium lineup includes 9000, S-Series, 9000 H-, 90000A and 90000 X Series oscilloscopes. These share a number of advanced hardware and software technology blocks. Use the following selection guide to determine which best matches your specific needs. Widest range of applications.
Agilent Infiniium 9000 Series oscilloscopes 15” XGA display makes it easier to view analog, digital and serial signals. Comprehensive built-in information system gives you fast answers to your questions. The task-oriented setup guide provides step-by-step instructions for several measurement procedures. Touchscreen display comes standard for mouse-free operation. Drag-and-drop measurements from the measurement bar provide an intuitive way to make a measurement on a particular cycle of your waveform.
Dedicated single acquisition button provides better control to capture a unique event. Pressing horizontal delay knob sets the delay to zero. A zoom button provides quick access to two screen-zoom modes. MegaZoom instant response and optimum resolution allows you to pan and zoom quickly. Autoscale lets you rapidly display any analog or digital active signals, automatically setting the vertical, horizontal and trigger controls for the best display, while optimizing memory.
Connectivity and probing Connectivity Probing Industry compatibility Each Ininiium 9000 Series oscilloscope ships with four N2873A 10:1 divider passive probes and probe accessory pouch. Export screen shots and waveforms in numerous industry-standard formats.
Infiniium 9000 Series performance characteristics Vertical: scope channels 9064A 9104A 9254A 9404A Analog bandwidth (–3 dB) 50 Ω1 1MΩ 600 MHz 500 MHz 1.0 GHz 500 MHz 2.5 GHz 500 MHz 4 GHz 500 MHz Typical Rise Time / Fall Time 10% to 90% at 50 Ω 540 ps 253 ps 142 ps 85 ps Typical Rise Time / Fall Time 20% to 80% at 50 Ω 360 ps 174 ps 98 ps 59 ps Input channels DSO9000 – 4 analog MSO9000 – 4 analog + 16 digital Input impedance1 50 Ω ± 2.
Infiniium 9000 Series performance characteristics Vertical: scope channels (con’t) Offset accuracy1,3 ± (1.
Infiniium 9000 Series performance characteristics Horizontal Channel-to-channel skew (digital) 2 ns typical Glitch detect (digital) ≥ 2.
Infiniium 9000 Series performance characteristics Acquisition 9104, 9254, 9404 9064 Maximum real-time sample rate 4 ch x 10 GS/s or 2 ch x 20 GS/s 4 ch x 5 GSa/s or 2 ch x 10 GSa/s Memory depth per channel Standard Option 50M Option 100 Option 200 Option 500 20 Mpts on 4 channels, 40 Mpts on 2 channels 50 Mpts on 4 channels, 100 Mpts on 2 channels 100 Mpts on 4 channels, 200 Mpts on 2 channels 200 Mpts on 4 channels, 400 Mpts on 2 channels 500 Mpts/ 250 Mpts on 4 channels, 1 Gpts/ 500 Mpts on 2 chann
Infiniium 9000 Series performance characteristics Trigger: digital channels MSO Models Threshold range (user defined) ±8.
Infiniium 9000 Series performance characteristics Trigger modes Edge (analog and digital) Triggers on a specified slope (rising, falling or alternating between rising and falling) and voltage level on any channel. Edge transition (analog) Trigger on rising or falling edges that cross two voltage levels in > or < the amount of time specified. Edge transition setting from 250 ps. Edge then edge (time) (analog and digital) The trigger is qualified by an edge.
Infiniium 9000 Series performance characteristics Display Display 15 inch color XGA TFT-LCD with touch screen Display intensity grayscale 64-level intensity-graded display Resolution 1024 pixels horizontally x 768 pixels vertically Annotation Up to 12 labels, with up to 100 characters each, can be inserted into the waveform area Grids Can display 1, 2 or 4 waveform grids Waveform styles Connected dots, dots, variable persistence, infinite persistence, color graded infinite persistence.
Infiniium 9000 Series performance characteristics General characteristics Temperature Operating 5 °C to + 40 °C Non-operating –40 °C to + 65 °C Humidity Operating Up to 95% relative humidity (non-condensing) at +40 °C Non-operating Up to 90% relative humidity at +65 °C Altitude Operating Up to 4,000 meters (12,000 feet) Non-operating Up to 15,300 meters (50,000 feet) Vibration Operating Random vibration 5-500 Hz, 10 minutes per axis, 0.
Infiniium 9000 Series ordering information How to configure an Infiniium 9000 Series Accessories included: 1. 2. 3. 4. 5. All models ship standard with: 1-year warranty, four N2873A 500 MHz passive probes, probe accessory pouch (mounts on rear of instrument), Agilent I/O libraries suite 15.0, localized power cord, front panel cover, keyboard, mouse, and stylus. User guide and programmer’s guide ship on oscilloscope hard drive. Service guide available on Agilent.com.
Infiniium 9000 Series ordering information SW Applications Fixed factory-installed option for new scope purchases Fixed user-installed product number (option -1NL or -1FP1) Floating user-installed floating licenses (N5435A option)2 RS-232/UART triggering and decode 001 N5462B 031 EZJIT jitter analysis software 002 E2681B 002 High-speed SDA and clock recovery 003 N5384A 003 EZJIT Plus jitter analysis software 004 N5400B 001 USB triggering and decode 005 N5464B 034 PCI Express 1.
Upgrades Memory upgrade Memory per scope channel (4-channel/ 2-channel mode) Factory-installed option for new scope purchases User-installed option (N2900A) 20 Mpts/40 Mpts Standard 020 50 Mpts/100 Mpts 50M 050 100 Mpts/200 Mpts 100 100 200 Mpts/400 Mpts 200 200 500 Mpts/1 Gpts 500 500 DSO to MSO upgrades (N2901A/B/C/D) Post-sales upgrades Upgrade your existing DSO to an MSO model in 5 minutes.
myAgilent myAgilent www.agilent.com/find/myagilent www.agilent.com www.agilent.com/ind/9000 A personalized view into the information most relevant to you. www.lxistandard.org LAN eXtensions for Instruments puts the power of Ethernet and the Web inside your test systems. Agilent is a founding member of the LXI consortium. For more information on Agilent Technologies’ products, applications or services, please contact your local Agilent office. The complete list is available at: www.agilent.