Product specifications

These linear-regulated DC power 
supplies provide reliable and conve-
nient DC power on a lab bench. The 
10-turn pots and clear voltage and 
current meters allow fine adjust-
ments to be made easily. These 
models are CV/CC, so they can 
serve as either voltage or current 
sources. The “CC Set” button allows 
the current setting to be viewed, 
allowing easy adjustment of a  
current limit. Either the positive or 
negative terminal may be connected 
to ground, creating a positive or 
negative voltage, or floated up to 
240 V from ground.
E3610A, E3611A, E3612A
These flexible 30 watt DC power 
supplies have 2 ranges, providing 
more current at lower voltage levels.
E3614A, E3615A, E3616A, E3617A
These DC power supplies provide 
remote sensing to eliminate the 
errors in voltage regulation due  
to voltage drops in the load leads. 
Delicate loads are protected by 
the overvoltage protection feature. 
Remote voltage signals can be used 
to control the power supply’s output 
voltage and current levels.
Basic DC Power Supplies   essential features for a tight budget
Spe cif icati ons
(at 0° to 55°C unless 
otherwise specified)
More detailed specifications at 
www.agilent.com/find/E3600
16
Small, compact size for bench use 
Low-noise and excellent regulation
Dual-range outputs (E3610A/11A/12A)
Overvoltage protection to ensure DUT safety
E3610A-E3617A
  Single-Output
  30-60 W 
    E3610A  E3611A  E3612A  E3614A
Number of output ranges    2  2  2  1
GPIB    No  No  No  No
Output ratings
1
Range 1    0 to 8 V,  0 to 20 V,  0 to 60 V,   0 to 8 V,  
    0 to 3 A
1
0 to 1.5 A
1
0 to 0.5 A
1
  0 to 6 A
Range 2    0 to 15 V,  0 to 35 V,   0 to 120 V,   —  
    0 to 2 A
1
  0 to 0.85 A
1
  0 to 0.25 A
1
Power (max)    30 W   30 W   30 W  48 W
Load and line regulation    0.01% + 2 mV  0.01% + 2 mV  0.01% + 2 mV  0.01% + 2 mV
Ripple and noise 
from 20 Hz to 20 MHz
Voltage rms    200 µV  200 µV  200 µV  200 µV
peak-peak    2 mV  2 mV  2 mV  1 mV 
 Supplemental Characteristics   (Non-warranted characteristics determined by design 
    that are useful in applying the product)
Control mode    CV/CC   CV/CC   CV/CC   CV/CC
Meter resolution  Voltage  10 mV  100 mV  100 mV  10 mV
(minimum change   Current  10 mA  10 mA  1 mA  10 mA 
using front-panel 
controls)
      For 0ff-the-shelf shipment 
1 
Maximum current is derated 1% per °C between 40° to 55°C.
Application notes
Understanding Linear Power 
Supply Operation (AN1554) 
5989-2291EN
10 Practical Tips You Need  
to Know About Your Power Products 
5965-8239E