Product specifications

These dual range DC power supplies 
provide the stable, accurate, and 
reliable DC power that the R&D  
engineer needs. These models are 
CV/CC, so they can serve as either 
voltage or current sources. They  
can be used either for manual or 
automated testing where moderate 
speed and accuracy are required. 
VXIPlug&Play drivers further 
simplify computer control.
These DC power supplies have many 
features to help the R&D engineer to 
quickly and easily bias and monitor 
prototype circuitry. Remote sensing 
eliminates the errors in voltage 
regulation due to voltage drops in 
the load leads. Delicate prototypes 
are protected by overvoltage and 
overcurrent protection features. 
Up to 3 frequently used operating 
states may be stored for later recall. 
The output is isolated from chassis 
ground.
For applications where even higher 
accuracy is needed, or speed must 
be optimized, see the Agilent 6600 
series of performance DC power 
supplies.
Basic DC Power Supplies   essential features for a tight budget
Spe cif icati ons
(at 0° to 55°C unless 
otherwise specified)
    E3632A   E3633A   E3634A   
More detailed specifications at 
www.agilent.com/find/E3600
20
Dual range outputs
Small, compact size for bench use
Low output ripple and noise 
Built-in measurements and basic programmable features 
Protection features to ensure DUT safety 
E3632A-E3634A
  Single-Output
  120 W to 200 W GPIB 
Number of outputs    1  1  1
GPIB    Yes  Yes  Yes
Output ratings
Range 1    0 to 15 V, 7 A  0 to 8 V, 20 A  0 to 25 V, 7 A
Range 2    0 to 30 V, 4 A   0 to 20 V, 10 A   0 to 50 V, 4 A
Load regulation 
Voltage     <0.01% + 2 mV  <0.01% + 2 mV  <0.01% + 2 mV
Current    <0.01% + 250 µA  <0.01% + 250 µA   <0.01% + 250 µA
Line regulation 
Voltage     <0.01% + 2 mV  <0.01% + 2 mV  <0.01% + 2 mV
Current    <0.01% + 250 µA  <0.01% + 250 µA   <0.01% + 250 µA
Ripple and noise   
from 20 Hz to 20 MHz
Normal-mode voltage    <350 µVrms/2 mVp-p  <350 µVrms/3 mVp-p  <500 µVrms/3 mVp-p
Normal-mode current    <2 mArms  <2 mArms  <2 mArms
Common-mode current    <1.5 µArms  <1.5 µArms   <1.5 µArms
Programming accuracy 
at 25°C ±5°C  
Voltage     0.05% + 10 mV  0.05% + 10 mV  0.05% + 10 mV
Current    0.2% +10 mA  0.2% +10 mA  0.2% +10 mA
Readback accuracy at 25°C ±5°C  
Voltage    0.05% + 5 mV  0.05% + 5 mV   0.05% + 5 mV
Current    0.15% + 5 mA   0.15% + 5 mA  0.15% + 5 mA
Resolution 
Program     1 mV, 0.5 mA  1 mV, 1 mA  3 mV, 0.5 mA
Readback    0.5 mV, 0.1 mA  0.5 mV, 1 mA  1.5 mV, 0.5 mA
Meter    1 mV, 1 mA  1 mV, 1 mA  1 mV, 1 mA 
      (<10 A/10 mA (≥10 A))  (<10 A/10 mA (≥10 A))
Transient response    50 µs for output to recover to within 15 mV following a change in output 
    current from full load to half load or vice versa
*Maximum current is derated 1% per °C from 40°C to 55°C % 
       For off-the-shelf shipment