Product specifications

This series of linear-regulated  
40-50 W DC power supplies is 
designed to maximize the  
throughput of DUTs through the 
manufacturing test process with 
fast programming and measurement, 
and also active downprogramming. 
It offers many advanced program-
mable features including stored 
states and status reporting. Pro-
gramming is done using industry 
standard SCPI commands via the 
GPIB or RS-232. Test system  
integration is further simplified by 
using the VXIPlug&Play drivers. 
The optional relays simplify system 
design and troubleshooting.
The half-rack size of the 6610A 
series makes it a convenient  
DC power supply for the R&D lab 
bench. The built-in microamp  
measurement system helps the  
engineer to easily and accurately 
monitor the output voltage and  
current without a complicated  
test setup.
Application notes
10 Practical Tips You Need to 
Know About Your Power Products
5965-8239E
10 Hints for Using Your Power Supply 
to Decrease Test Time
5968-6359E
Understanding Linear Power Supply
Operation (AN1554)
5989-2291EN
High Performance DC Power Supplies   speed and accuracy for test optimization
More detailed specifications at 
www.agilent.com/find/6610
38
Small, compact size for bench and system use
Fast, low-noise outputs
Dual-range, precision low current measurement
Built-in measurements and advanced programmable features 
Protection features to ensure DUT safety
6611C - 6614C
  Single-Output
  40-50 W GPIB 
Spe cif icati ons
(at 0° to 55°C unless 
otherwise specified)
      6611C  6612C  6613C   6614C  6611C-
              J05
Special order
              option
Number of outputs    1  1  1  1  1
GPIB    Yes  Yes  Yes  Yes  Yes
Output ratings 
Voltage    0 to 8 V  0 to 20 V  0 to 50 V  0 to 100 V  0 to 10 V 
Current    0 to 5 A  0 to 2 A  0 to 1 A   0 to 0.5 A  0 to 5 A
Programming accuracy (at 25°C ±5°C) 
Voltage    5 mV  10 mV  20 mV   50 mV   5 mV
+Current   0.05% +  2 mA   1 mA   0.75 mA  0.5 mA  2 mA
Ripple and noise  20 Hz to 20 MHz, with outputs 
ungrounded  or with either terminal grounded 
Voltage  rms  0.5 mV  0.5 mV  0.5 mV  0.5 mV  0.5 mV 
  peak -to-peak  3 mV   3 mV   4 mV   5 mV  3 mV
Normal mode  rms   2 mA   1 mA   1 mA   1 mA  2 mA
DC measurement accuracy via GPIB or front-panel  
meters with respect to actual output at 25°C ±5°C 
Voltage  0.03% +   2 mV   3 mV   6 mV   12 mV  2 mV
Low current range  -20 mA to + 20 mA    0.1% +  2.5 µA   2.5 µA   2.5 µA   2.5 µA  2.5 µA
High current range +20 mA to + rated 1     0.2% +  0.5 mA   0.25 mA   0.2 mA   0.1 mA  0.5 mA 
  -20 mA to - rated 1    0.2% +  1.1 mA   0.85 mA   0.8 mA   0.7 mA  1.1 mA
Load regulation
Voltage    2 mV   2 mV   4 mV  5 mV  2 mV
Current    1 mA  0.5 mA  0.5 mA  0.5 mA  1 mA
Line regulation
Voltage    0.5 mV  0.5 mV  1 mV  1 mV  0.5 mV
Current     0.5 mA   0.5 mA  0.25 mA   0.25 mA  0.5 mA
Transient response time Less than 100 µs for the output to recover to its previous level (within 0.1% of the voltage 
rating of the supply or 20 mV, whichever is greater) following any step change in load current of up to 50% of the 
output current rating of the supply 
Supplemental Characteristics
    (Non-warranted characteristics determined by design and 
    useful in applying the product)
Average programming resolution  
Voltage    2 mV  5 mV  12.5 mV  25 mV  3 mV
Current     1.25 mA  0.5 mA  0.25 mA   0.125 mA  1.25 mA
Sink current    3 A   1.2 A   0.6 A   0.3 A  3 A