Product specifications

This series of 200 W linear-regulated 
DC power supplies is designed to 
maximize the throughput of DUTs 
through the manufacturing test 
process with fast up and down 
programming time. 
Valuable assemblies can be 
destroyed by a minor component 
failure that can allow a surge of 
voltage or current to flow to the 
DUT. Fast protection features,  
including fast crowbar, mode cross-
over protection, and the ability to 
connect the protection circuitry 
of multiple power supplies can 
increase production yield.
Programming of the DC output and 
the protection features can be done 
either from the front panel or using 
industry standard SCPI commands, 
via the GPIB. Using the serial link, 
up to 16 power supplies can be  
connected through one GPIB 
address. Test system integration  
can be further simplified be using 
the VXIPlug&Play drivers. The out-
put voltage and current can also be 
controlled with analog signals. This 
is helpful for certain types of noisy 
environments, and also immediate 
reactions to process changes.
Lab bench use is enhanced by the 
fan speed control, which helps to 
minimize the acoustic noise. 
High Performance DC Power Supplies   speed and accuracy for test optimization
Spe cif icati ons
(at 0° to 55°C unless 
otherwise specified)
More detailed specifications at 
www.agilent.com/find/6640
42
Fast, low-noise outputs
Analog control of output voltage and current 
Fan-speed control to minimize acoustic noise
Parallel and series connections of multiple units
Built-in measurements and advanced programmable features 
Protection features to ensure DUT safety
6641A - 6645A
  Single-Output
  200 W 
GPIB 
    6641A   6642A  6643A   6644A  6645A
Number of outputs
    1  1  1  1  1
GPIB
    Yes  Yes  Yes  Yes  Yes
Output ratings 
Output voltage     0 to 8 V  0 to 20 V  0 to 35 V   0 to 60 V  0 to 120 V
Output current (40°C)    0 to 20 A  0 to 10 A   0 to 6 A   0 to 3.5 A  0 to 1.5 A
Maximum current (50°C/55°C)    18 A/17 A   9 A/8.5 A  5.4 A/5.1 A  3.2 A/3 A   1.4 A/1.3 A
Programming accuracy at 25°C ±5°C 
Voltage  0.06% +  5 mV  10 mV  15 mV  26 mV  51 mV
Current  0.15% +  26 mA  13 mA  6.7 mA  4.1 mA  1.7 mA
Ripple and noise 
from 20 Hz to 20 MHz
Voltage  rms  300 µV  300 µV  400 µV  500 µV   700 µV
  peak-peak  3 mV  3 mV  4 mV  5 mV  7 mV
Current  rms  10 mA  5 mA  3 mA  1.5 mA  1 mA
Readback accuracy at 25°C ±5°C 
(percent of reading plus fixed)
Voltage  0.07% +  6 mV  15 mV  25 mV  40 mV  80 mV
+Current  0.15% +  18 mA  9.1 mA   5 mA   3 mA  1.3 mA
-Current  0.35% +  40 mA   20 mA  12 mA  6.8 mA  2.9 mA
Load regulation 
Voltage    1 mV  2 mV  3 mV  4 mV  5 mV
Current    1 mA  0.5 mA  0.25 mA  0.25 mA  0.25 mA
Line regualtion 
Voltage    0.5 mV  0.5 mV  1 mV  1mV   2 mV
Current    1 mA  0.5 mA  0.25 mA  0.25 mA  0.25 mA
Transient response time  Less than 100 µs for the output voltage to recover to its previous level (within 0.1% of 
the voltage rating of the supply or 20 mV, whichever is greater) following any step change in load current of up to 
50% of rated current
  Supplemental Characteristics  (Non-warranted characteristics determined by design and 
    useful in applying the product)
Average resolution 
Voltage     2 mV  5 mV  10 mV  15 mV   30 mV
Current    6 mA  3 mA  2 mA  1.2 mA  0.5 mA
OVP     13 mV  30 mV  54 mV  93 mV   190 mV
OVP accuracy    160 mV  400 mV  700 mV  1.2 V   2.4 V