Product specifications

80
  Low-Profile Modular Power System
   20-500 W GPIB (Continued)
  M
ore detailed specifications at 
www.agilent.com/find/N6700
High Performance DC Power Supplies   speed and accuracy for test optimization
Spe cif icati ons
(at 0° to 55°C, and 
derated above 40°C)
    N6761A  N6762A  N6763A  N6764A  N6765A  N6766A 
Supplemental Characteristics 
      (Non-warranted characteristics determined by design 
                                             that are useful in applying the product)
Measurement temperature coefficient per 
°C
Voltage, high range    23 ppm +   23 ppm +   23 ppm +  23 ppm +   23 ppm +   23 ppm +  
      40 µV  40 µV  53 µV  73 µV  53 µV  73 µV
Voltage, low range    30 ppm +   30 ppm +  25 ppm +   25 ppm +   25 ppm +  25 ppm +  
      40 µV  40 µV  53 µV  73 µV  53 µV  73 µV
Current, high range    40 ppm +   40 ppm +   25 ppm +   25 ppm +  25 ppm +  25 ppm +  
      0.3 µA  0.3 µA  21 µA  7 µA  21 µA  7 µA
Current, low range    50 ppm +   50 ppm +   27 ppm +  27 ppm +   27 ppm +   27 ppm +  
      0.3 µA  0.3 µA  21 µA  7 µA  21 µA  7 µA
200 µA current range (option 2UA)  100 ppm +  100 ppm +   N/A  N/A  N/A  N/A 
      3 nA/
°C
  3 nA/
°C
N6705 mainframe oscilloscope measurement accuracy: 
(at 23°C ±5°C, accuracy of any individual point in the trace)
Voltage    0.016% +   0.016% +  0.03% +   0.03% +  0.03% +   0.03% +  
      16 mV  16 mV  13 mV  32 mV  13 mV  32 mV
Current, high range     0.04% +  0.04% +  N/A   N/A  N/A  N/A 
(with Correction On
1
)    10 mA  10 mA 
Current, high range     0.04% +  0.04% +  0.1% +  0.1% +  0.1% +   0.1% + 
    1 mA  1 mA  16 mA  8.4 mA  16 mA  8.4 mA
Current, low range     0.03% +   0.03% +   0.05% +  0.05% +  0.05% +   0.05% + 
    0.175 mA  0.175 mA  6.6 mA  2.6 mA  6.6 mA  2.6 mA
Up-programming time with full resistive load: 
(time from 10% to 90% of total voltage excursion)
Small voltage step   
0 V to 10 V  0 V to 10 V  0 V to 6 V  0 V to 15 V   0 V to 10 V  0 V to 29 V
Time    0.6 ms  0.6 ms  0.4 ms  0.35 ms   0.5 ms  0.7 ms
Large voltage step   
0 V to 50 V  0 V to 50 V  0 V to 20 V  0 V to 60 V   0 V to 20 V  0 V to 60 V
Time    2.2 ms  2.2 ms  1.5 ms  2 ms  1.5 ms  2 ms
Up-programming settling time with full resistive load: 
(time from start of voltage change to within 0.1% of full scale value)
Small voltage step   
0 V to 10 V  0 V to 10 V  0 V to 6 V  0 V to 15 V   0 V to 10 V  0 V to 29 V
Time    0.9 ms  0.9 ms  0.8 ms  0.8 ms   1.0 ms  1.4 ms
Large voltage step   
0 V to 50 V  0 V to 50 V  0 V to 20 V  0 V to 60 V   0 V to 20 V
0 V to 60 V
Time    4 ms  4 ms  3 ms  4.2 ms  3 ms  4.2 ms
Down-programming time with no load: 
(time from start of voltage change to output voltge <0.5 V)
Small voltage step   
10 V to 0 V  10 V to 0 V  6 V to 0 V  15 V to 0 V   10 V to 0 V  29 V to 0 V
Time    0.3 ms  0.3 ms  0.55 ms  0.6 ms   1.0 ms  1.2 ms
Large voltage step   
50 V to 0 V  50 V to 0 V  20 V to 0 V  60 V to 0 V  20 V to 0 V  60 V to 0 V
Time    1.3 ms  1.3 ms  1.8 ms  2.2 ms   1.8 ms  2.2 ms
Down-programming setting time with no load: 
(time from start of voltage change to within 0.1% of full scale value)
Small voltage step   
10 V to 0 V  10 V to 0 V  6 V to 0 V  15 V to 0 V   10 V to 0 V  29 V to 0 V
Time    0.45 ms  0.45 ms  0.8 ms  0.8 ms  1.3 ms  1.5 ms
Large voltage step   
50 V to 0 V  50 V to 0 V  20 V to 0 V  60 V to 0 V  20 V to 0 V  60 V to 0 V
Time    1.4 ms  1.4 ms  2 ms  2.3 ms   2 ms  2.3 ms
1
Correction On compensates for current flowing into the output capacitor during voltage transients
N6750 family
The Agilent N6750 family of high-
performance, autoranging DC power 
modules provides low noise, high 
accuracy and includes, auto-ranging 
output capabilities enabling one 
power supply to do the job of sev-
eral traditional power supplies. 
N6760 family
The Agilent N6760 family of precision 
DC power modules provides precise 
control and measurements in the 
milliampere and microampere 
region with the ability to simultane-
ously digitize voltage and current, 
and capture those measurements 
in an oscilloscope-like data buffer. 
The N6761A/N6762A precision DC
power modules offer dual ranges on
both programming and measurement 
while the N6763A-N6766A offer 
dual measurement ranges. All are 
ideally suited for semiconductor 
and passive device testing.
N6750/60 low noise outputs
This switching power supply  
outperforms most linear power 
supplies on the market with low 
normal and common mode noise.