Product specifications

89
66000 MPS mainframe. For applica-
tions with a broader range of power
requirements, one 66000 mainframe 
can be connected with up to eight of 
the 6640, 6650, 6670, 6680, 6690 or 
6030 series of system power sup-
plies. This solution provides power 
ranges from 150 watts to 5000 watts 
at one primary GPIB address.
Output connections
System assembly is simplified 
thanks to a quick-disconnect connec-
tor assembly on each module. Once 
your wires are connected to the 
load, the connector design permits 
the modules to be removed from 
the front of the mainframe without 
disconnecting cabling or removing 
the mainframe from the rack. One 
connector assembly is shipped with 
each module. 
Output sequencing
Increase test throughput by using 
the output sequencing feature
of the 66000 MPS. This powerful  
feature allows you to download
up to 20 voltage, current, and 
dwell-time parameter sets per out-
put. This sequence can be paced by 
the programmed dwell times. As an 
alternative, triggers can be used to 
step through the output list. The  
output sequences can be executed 
without controller intervention, 
thereby increasing overall test 
system throughput. More detailed 
information on the triggering and 
output sequencing capabilities can 
be obtained by ordering the 66000
Modular Power System Product Note 
(p/n 5091-2497E).
  Modular Power System 
  1200 W per mainframe GPIB (Continued)
Spe cif icati ons
(at 0° to 55°C unless 
otherwise specified)
    66101A-  66101A-  66102A-  66103A-  66103A-
    J03  J05  J05  J01  J02
Special order  Special order  Special order  Special order  Special order
    option  option  option  option  option
Output ratings at 40°C 
Output voltage    5.7 V  12 V  15 V  37 V  40 V
Output current    20 A  12 A  10 A  4.5 A  3.6 A
Maximum power    114 W  144 W  150 W  167 W  144 W
Programming accuracy
  at 25°C ±5°C
Voltage     0.03% +  2.5 mV  5 mV  8 mV  13 mV  15 mV
Current    0.03% +  8 mA  6 mA  4 mA  2 mA  2 mA
Readback accuracy   
(via GPIB keyboard display   
at 25°C ±5°C)
Voltage       0.02% +  2 mV  3 mV  5 mV  8 mV  9.2 mV
Current    0.02% +  8 mA  6 mA  4 mA  2 mA  2 mA
Ripple and noise  (20 Hz to 20 MHz)
Constant voltage rms    2 mV  3 mV  3 mV  5.3 mV  6 mV
peak-peak    5 mV  7 mV  7 mV  10.6 mV  11.5 mV
Constant current rms    10 mA  8 mA  6 mA  2 mA  2 mA
Line regulation 
Voltage    0.5 mV  0.5 mV  0.5 mV  1 mV  1 mV
Current    0.5 mA  0.75 mA  0.5 mA  0.3 mA  0.3 mA
Load regulation 
Voltage    1 mV  1 mV  1 mV  1 mV  1 mV
Current    1 mA  0.5 mA  0.3 mA  0.2 mA  0.2 mA
Transient response time    Less than 1 ms for the output voltage to recover within 100 mV of its 
    previous level following any step change in load current up to 10 percent 
    of rated current
 Supplemental Characteristics   (Non-warranted characteristics determined by design  
    that are useful in applying the product)
Average resolution 
Voltage    2 mV  3.6 mV  4.5 mV  11 mV  12 mV
Current    6 mA  4.6 mA  3.1 mA  1.4 mA  1.2 mA
OVP    45 mV  75 mV  90 mV  200 mV  230 mV
OVP accuracy    250 mV  375 mV  375 mV  850 mV  920 mV 
More detailed specifications at 
www.agilent.com/find/66000
High Performance DC Power Supplies   speed and accuracy for test optimization
Application notes
66000 Modular Power System 
Product Note
5988-2800EN
10 Practical Tips You Need to 
Know About Your Power Products
5965-8239E
10 Hints for Using Your Power Supply 
to Decrease Test Time
5968-6359E
Agilent DC Power Supplies 
for Base Station Testing
5988-2386EN