User`s guide
100 N9320A Spectrum Analyzer
4 Key Reference
Marker->
Press   accesses the following marker function softkeys:
Mkr CF Sets the frequency of the marker to the center frequency. In 
delta mode, Mkr CF  sets the displayed trace center 
frequency to the frequency of the marker delta value. 
Mkr CF  is not available in zero span.
Key access: 
Mkr CF Step Changes the center- frequency step size to match the value of 
the active marker. Press   > CF Step to view the step 
size. The step size is the frequency difference between the 
markers when marker delta is active. Use this function to 
step from one signal harmonic to another. Mkr CF Step  is 
not available in zero span.
Key access: 
Mkr Start Changes the display start frequency to the frequency of the 
active marker. In delta mode, Mkr Start  sets the start 
frequency to the marker delta value. Mkr Start  is not 
available in zero span.
Key access: 
Mkr Stop Changes the stop frequency to the frequency of the active 
marker. In Delta mode, Mkr Stop  sets the stop frequency to 
the marker delta value. Mkr Stop  is not available in zero 
span.
Key access: 
Mkr Ref Lel Changes the reference level to the active marker value, 
moving the marked point to the reference level (top line of 
the graticule). In delta mode, Mkr Ref Lel  sets the reference 
level to the amplitude difference between the markers. (For 
example, if the difference is –15 dB, the reference level –15 
dBm.)
Key access: 
Marker
Marker
Frequency
Marker
Marker
Marker
Marker










