SCPI Command Reference 6
N9340A User’s Guide 123
CALCulate:MARKer Subsection
Markers All Off on All Traces
:CALCulate:MARKer:AOFF
This command turns off all markers on all traces.
Markers All On
:CALCulate:MARKer:ALL
This command turns on all the markers and places
them on the six highest peaks.
Frequency Counter Marker
:CALCulate:MARKer[1]|2|3|4|5|6:FCOunt
[:STATe] OFF|ON|0|1
:CALCulate:MARKer[1]|2|3|4|5|6:FCOunt
[:STATe]?
This command toggles the frequency counter
between on and off.
To query frequency counter readout, use
:CALCulate:MARKer[1]|2|3|4|5|6:FRECount:X?
Key access: [Marker] > {More} > {All Off}
*RST state: Off
Key access: [Marker] > {Peak search} > {Auto search}
*RST state: Off