Model no. U1211A U1212A U1213A U1191A U1192A
U1193A
U1194A
Display
Display resolution (counts) 4,000 4,000 4,000 6,000 6,000 6,000 6,000
Dual display Yes Yes Yes No No No No
Analog bar-graph Yes Yes Yes No No No No
Back-light Yes Yes Yes Yes Yes Yes Yes
Basic features
AC bandwidth 400 Hz 400 Hz 2 kHz 500 Hz 500 Hz 500 Hz 500 Hz
RMS Method True RMS AC AC AC + DC
Average
responding
Average
responding
True RMS True RMS
Auto/manual ranging Yes Yes Yes Auto ranging only Auto ranging only Auto ranging only Auto ranging only
Measurements
Voltage AC/DC: Range 400 to 1000 V 400 to 1000 V 4 V to 1000 V 600 V 60 to 600 V 60 to 600 V 60 to 600 V
Current AC/DC: Range ACI: 40 to 1000 A
40 to
1000A
40 to
1000A
ACI: 400 A
ACI: 60 to
400 A
ACI: 60 to
600 A
ACI: 60 µA to
600 A
DCI: 60 µA to
600 A
Resistance: Range 400 Ω to 4kΩ 400 Ω to 4kΩ 400 Ω to 40MΩ 600 Ω to 6 kΩ 600 Ω to 60 kΩ 600 Ω to 60 kΩ 600 Ω to 60 kΩ
Frequency: Range
99.99 Hz to
999.9 kHz
99.99 Hz to
999.9 kHz
99.99 Hz to
999.9 kHz
N/A
99.99 Hz to
99.99 kHz
99.99 Hz to
99.99 kHz
99.99 Hz to
99.99 kHz
Capacitance: Range 400 to 4000μF 400 to 4000µF 4 to 4000µF N/A 600 μF to 6 mF 600 μF to 6 mF 600 μF to 6 mF
Temperature: Type, range N/A
K: –200 to
1372 °C
K: –200 to
1372 °C
N/A N/A N/A
K-type: –40 to
1200 °C
Continuity with beeper Yes Yes Yes Yes Yes Yes Yes
Diode test Yes Yes Yes Yes Yes Yes Yes
Data management
Min/max recording Yes Yes Yes Yes Yes Yes Yes
Display hold Yes Yes Yes Yes Yes Yes Yes
Peak hold Yes Yes Yes N/A N/A N/A N/A
Null Yes Yes Yes Yes Yes Yes Yes
Connectivity Bluetooth Bluetooth Bluetooth N/A N/A N/A N/A
General
Operating temperature
–10 to 50 °C,
0 to 80% RH
–10 to 50 °C,
0 to 80% RH
–10 to 50 °C,
0 to 80% RH
–10 to 50 °C,
0 to 80% RH
–10 to 50 °C,
0 to 80% RH
–10 to 50 °C,
0 to 80% RH
–10 to 50 °C,
0 to 80% RH
Measurement category
CAT III 1000 V /
CAT IV 600 V
CAT III 1000 V /
CAT IV 600 V
CAT III 1000 V /
CAT IV 600 V
CAT III 600 V /
CAT IV 300 V
CAT III 600 V /
CAT IV 300 V
CAT III 600 V /
CAT IV 300 V
CAT III 600 V /
CAT IV 300 V
Battery type (included) 9 V 9 V 9 V 1.5 V 1.5 V 1.5 V 1.5 V
Battery life 60 hours 60 hours 60 hours 200 hours 200 hours 200 hours 200 hours
Dimensions (H x W x D)
273.0 x
106.0 x
43.0 mm
273.0 x
106.0 x
43.0 mm
273.0 x
106.0 x
43.0 mm
225.0 x
77.1 x
38.6 mm
225.0 x
77.1 x
38.6 mm
238.0 x
77.1 x
38.6 mm
238.0 x
77.1 x
38.6 mm
Clamp opening 52 mm / 2 " 52 mm / 2 " 52 mm / 2 " 31 mm 31 mm 37 mm 37 mm
Advanced functions Auto power off Auto power off Auto power off
Wire separator,
Auto power off
Wire separator,
built-in flashlight,
Vsense,
Auto power off
Wire separator,
built-in flashlight,
Vsense,
Auto power off
Wire separator,
built-in flashlight,
Vsense,
Auto power off
Clamp Meters