Specifications

19
PNA Family Network Analyzer Upgrade Kits (continued)
Application options
Upgrade kits are available to add options after initial purchase. To upgrade the PNA-X/PNA/PNA-L, order the corresponding
item number. The model and serial numbers of the instrument to be retrofitted are required as part of the order.
1. For measuring frequency converters, Option 082 or 083 is required.
2. Requires configurable test set for signal conditioning of noise figure measurements using standard receivers. Therefore it is not available with
N522xA-200 and -400.
3. Two-tone signal must be routed to R1 receiver after an external combiner; therefore it is not available with N522xA-200 and 400.
4. When used with an external signal generator, configurable test set is required to access a receiver. Therefore it is not available with N522xA-200.
5. To connect a multiport test set, configurable test set is required. Therefore it is not available with N522xA-200/400, and N523xA-200/400.
Description Required Option
For PNA-X
Series
For PNA
Series
For PNA-L
Series
User
Installable
Measurement applications
Time-domain measurements N524xAU-010 N522xAU-010 N523xAU-010 Yes
Noise figure measurements using standard
receivers
Option 080
1,2
N524xAU-028 N522xAU-028 n/a Yes
Fully-corrected noise figure measurements
for PNA-X, 2-ports
Option 080 and for N5241/42A, one
of Options 219, 224 or H85
1
.
For N5244/45/47A, 080 and 224
N524xAU-924 n/a n/a No
Fully-corrected noise figure measurements
for PNA-X, 4-ports
Option 080 and for N5241/42A, one
of Options 419, 423 or H85
1
.
For N5244/45/47A, 080 and 423
N524xAU-929 n/a n/a No
Frequency offset N524xAU-080 N522xAU-080 N523xAU-080 Yes
Scalar-calibrated converter measurements Option 080 N524xAU-082 N522xAU-082 N523xAU-082 Yes
Vector- and scalar-calibrated converter
measurements
Option 080 N524xAU-083 N522xAU-083 n/a Yes
Embedded LO measurements Option 082 or 083 N524xAU-084 N522xAU-084 n/a Yes
Gain compression application See Footnote 1 N524xAU-086 N522xAU-086 n/a Yes
Intermodulation distortion application Option 080
1,3
N524xAU-087 N522xAU-087 n/a Yes
Source phase control See Footnote 4 N524xAU-088 N522xAU-088 n/a Ye s
Integrated true-mode stimulus application Option 400, 401, 417, 419, or 423 N524xAU-460 N522xAU-460 n/a Ye s
N-port capabilities See Footnote 5 N524xAU-551 N522xAU-551 N523xAU-551 Yes
Pulse, antenna, mm-wave
Pulsed-RF measurements Option 025
1
N524xAU-008 N522xAU-008 n/a Yes
Add IF inputs N524xAU-020 N522xAU-020 n/a Yes
Add pulse modulator to internal 1st source N524xAU-021 N522xAU-021 n/a Yes
Add pulse modulator to internal 2nd source Option 224, 400, 401, 417, 419, or 423 N524xAU-022 N522xAU-022 n/a Yes
Add four internal pulse generators N524xAU-425 N522xAU-425 n/a Yes
Fast CW sweep N524xAU-118 N522xAU-118 n/a Yes
Nonlinear network vector analysis
Nonlinear component characterization Options 419 and 080, or 400, H85
and 080
N524xAU-510 n/a n/a Yes
Nonlinear X-parameters
Options 423 and 510 N524xAU-514 n/a n/a Yes
Nonlinear pulse envelope domain Requries Options 021, 025 and
either one of 510 or 514
N524xAU-518 n/a n/a Yes
Arbitrary load-impedance X-parameters Option 514 N524xAU-520 n/a n/a Yes
Calibration software
Perpetual license for built-in performance
test software for Agilent inclusive calibration
N524xAU-897 N522xAU-897 N523xAU-897 Yes
Perpetual license for built-in performance
test software for standard compliant
calibration
N524xAU-898 N522xAU-898 N523xAU-898 Yes