Specifications

9
The PNA is an integrated vector network analyzer featuring a
built-in S-parameter test set, one or two synthesized sources
used for device stimulus, a solid-state drive, USB interfaces, and
a 10.4” LCD touch screen display. The N5221A and the N5222A
have 50 ohm, ruggedized 3.5 mm (m) test ports. The N5224A and
the N5225A have 50 ohm, ruggedized 2.4 mm (m) test ports.
The N5227A has a 50 ohm, ruggedized 1.85 mm (m) test ports.
Included with each instrument is a mouse, keyboard (U.S. style),
a 1-year return-to-Agilent service warranty, and one day of on-
site productivity assistance (PS-S20-PNA).
A test set and power configuration option is mandatory, choose
one of the following:
2-ports, single source, base configuration (Option 200)
The 2-port with base configuration has no front-panel access
loops.
2-ports, single source, with configurable test set (Option 201)
The 2-port configurable test set comes with six front-panel
access loops. The loops provide access to the signal path
between (a) the source output and the reference receiver, (b)
the source output and directional coupler thru arm and (c) the
coupled arm of the directional coupler and the port receiver at
all ports. Also included is a solid-state internal RF transfer
switch in the R1 reference-receiver path.
2-ports, single source, with extended power range (Option 217)
The 2-port test set with extended power range comes with a
configurable test set, source and receiver attenuators at each
port. For N5221/22A, the source attenuators are 65 dB in 5 dB
steps and the receiver attenuators are 35 dB in 5 dB steps. For
N5224/25A, the source attenuators are 60 dB in 10 dB steps
and the receiver attenuators are 35 dB in 5 dB steps. Also
included is a solid-state internal RF transfer switch in the R1
reference-receiver path. This configuration is not available on
N5227A.
2-ports, single source, with extended power range and bias-tee
(Option 219)
The 2-port test set with extended power range and bias-tee
comes with a configurable test set, source and receiver
attenuators, and bias-tee at each port. For N5221/22A, the
source attenuators are 65 dB in 5 dB steps and the receiver
attenuators are 35 dB in 5 dB steps. For N5224/25A, the
source attenuators are 60 dB in 10 dB steps and the receiver
attenuators are 35 dB in 5 dB steps. For N5227A, both source
and receiver attenuators are 50 dB in 10 dB steps. Also
included is a solid-state internal RF transfer switch in the R1
reference-receiver path.
PNA Series test set and power configuration options
Te st port 1 Te st port 2
A B
R1
R2
Source
OUT 1OUT 2
Pulse
modulator
To receivers
LO
Pulse generators
RABC D
IF inputs
rear panel
R1
R2
35 dB
65 dB 65 dB
A
35 dB
B
Source
OUT 1OUT 2
Pulse
modulator
To receivers
LO
Pulse generators
RABC D
IF inputs
rear panel
Te st port 1
R1
Te st port 2
R2
A B
Source
OUT 1OUT 2
Pulse
modulator
To receivers
LO
Pulse generators
RABC D
IF inputs
rear panel
Te st port 1
R1
Te st port 2
R2
35 dB
65 dB 65 dB
A
35 dB
B
Source
OUT 1OUT 2
Pulse
modulator
To receivers
LO
Pulse generators
RABC D
IF inputs
rear panel