ADDENDUM to the Agilent Model 6813B User's Guide and Service Manual for the 2000 VA Output Capability Option 019 Agilent P/N 5964-8149 Microfiche No 5964-8150 Printed in U.S.A.
000 VA Output Capability The 2000 VA Output Capability Option 019 is available on the following ac source model: Agilent 6813B Option 019 AC Power Source (2000VA) Option 019 increases the output VA capability of the standard Agilent 6813B AC Power Source from 1750 VA to 2000 VA. To achieve the increased output VA capability, the output rms voltage, dc voltage and rms current ratings have increased slightly, to the maximum ratings documented in Table A-1.
Verification and Calibration for Option 019 There are no changes to the output verification and calibration sections of the User's Guide for units with Option 019. Option 019 Factory Modifications Make the following changes to the Agilent 6813B Service Manual (p/n 5962-0859) for Agilent 6813B Option 019 units. Initialization For ROM revision A.00.07, change step 3 to “Scroll to 6813J02 and press Enter”. NOTE: Option J02 and Option 019 are identical; the J02 option was renamed option 019.