User's Manual

08/10/2007 Vertraulich / Confidential Page 18 of 31
AWR100
The configuration of the Stick Reader can be reset to the factory settings by pressing the read
button.
After a successful resetting of the configuration
appears on the second line of the LCD display for a certain time.
4.3.8 Online / offline
The Stick Reader provides an online- and an offline mode. In online mode transponder data are
transmitted immediately via RS232 interface or Bluetooth. In offline mode transponder data are
only stored in the database of the Stick Reader but not transmitted.
If the Stick Reader is in online mode, the following text appears on the second line of the LCD
display:
If the Stick Reader is in offline mode, the following text appears on the second line of the LCD
display:
The mode could be changed by pressing the read button.
4.3.9 Next Group
It is possible to separate groups of transponders by inserting a new group pattern in the data-
base of the Stick Reader. In this case the Stick Reader stores a zero transponder at the current
position of the database and the animal counter is automatically reset to zero.
For this option the following text appears on the second line of the LCD display:
A new group is inserted by pressing the read button.
4.3.10 Show last IDs
With this option it is possible to show up to three last read transponders after Stick Reader was
switched on.
For this option the following text appears on the second line of the LCD display:
The feature is started by pressing the read button.
If no transponders were read after switching on the Stick Reader the following text appears on
the second line of the LCD display:
Agrident V1.04
Done
Agrident V1.04
->Online mode
Agrident V1.04
->Offline mode
Agrident V1.04
->Next group
Agrident V1.04
-> Show last IDs
Agrident V1.04
No IDs available