Operation Manual

MIDI2 CHANNELL (OUT)
Swell = 1
> Great = 2
Pedal = 4
Common = 16
PRAELUDIUM III - PRAELUDIUM IV/E - User's Manual
MIDI SETTING
AHLBORN Classical Organs
English Page 42
To select MIDI channels by section, both in entrance - MIDI Channel (IN) - and in exit - MIDI Channel (OUT) - it
is possible to assign to the various sections (Swell-Great-Pedal and Common) a MIDI channel from 1 to 16 or to
exclude it completely by positioning the channel on OFF. The display shows an example for the setting of MIDI
2 Channel (OUT). The following MIDI functions are also available:
The control (see SYSTEM PANEL N.2) permits to execute the following MIDI settings:
REMINDER !
If this function is set as External on MIDI 1, it will automatically be forced as Internal by MIDI 2.
if the organ is connected via MIDI with the external Sequencer, it is possible to select the use of INTERNAL
or EXTERNAL CLOCK with this control.
By activating this control it is possible to pass all incoming MIDI messages (MIDI 1 IN) to the exit (MIDI 1
OUT) directly, without passing through the instrument. In this case the MIDI 1 OUT socket also operates
the MIDI 1 THRU socket.
MIDI 1
1
MIDI2
2
MIDI PIPE
3
MIDI 1
1
SOFTWARE THRU
A
SEQUENCER CLOCK
B