Instruction Manual

LCU-ONE CAN connected to MXL QM and EVO3 QM
User Manual
Release 1.04
In case of an EVO3 QM, data visualisation is only possible if the logger is connected to a
Formula Steering Wheel or to a MyChron3 Dash and displayed channels are set in that
display configuration, as shown below.
Note: LCC_diagnosys channel shows LCU-ONE working status and can show up to four
messages:
0: status OK
1: probe not connected
2: +12V short circuit
3: GND short circuit
The configuration is now ready to be transmitted to the logger.
Warning: configuration has to be repeated for all LCU-ONE connected to the logger.
Press “Transmit” button on DragOn top keyboard. If the transmission is ok no message is
shown. If, LCU-ONE serial number has not been get, the window here below appears. It
tells the user that no serial number has been assigned to the connected expansion. Close
this window button and get the expansion serial number as explained before.
www.aim-sportline.com 17