PORTABLE INVERTER GENERATOR GEN6600W240VS 120/240V IMPORTANT ─READ AND UNDERSTAND THE MANUAL PRIOR TO USING, KEEP MANUAL FOR REFERENCE.
CONTENTS SAFETY INFORMATION...............................................................................................................................................2 CONTROL & FEATURES..............................................................................................................................................4 PRE-OPERATION CHECK ...........................................................................................................................................6 OPERATION........
WARNING PLEASE READ AND UNDERSTAND THIS MANUAL COMPLETELY BEFORE OPERATING THE GENERATOR SAFETY INFORMATION 1) EXHAUST FUMES ARE POISONOUS Never operate the engine in a closed area or it may cause unconsciousness or death within a short period of time. Operate the engine in a well ventilated area. 2) FUEL IS HIGHLY FLAMMABLE AND POISONOUS Always turn off the engine when refueling. Never refuel while smoking or around an open flame.
5) CONNECTION NOTES Do not connect the generator to commercial power outlet. Do not connect the generator in parallel with any other generator. SAFETY SYMBOLS Caution - The user should be aware of a general hazard. Dangerous Voltage Flammable Hot Surface - Do not touch.
CONTROL & FEATURES (1) Spark plug (2) Fuel tank (3) Fuel tank cap (4) Fuel filter (5) Carrying handle (6) Fuel level gauge (7) Muffler (8) Battery (9) Air filter (10) Brake lever (11) Wheel (12) Oil filler cap (13) Oil drain plug (14) AC pilot light (15) Overload indicator light (16) Oil warning light (17) Engine switch (18) DC receptacle (19) DC protector (20) USB Output (21) AC receptacle 5-20R GFCI (22) Ground (earth) terminal (23) AC receptacle L14-30R 120/240V (24) Auto gen start
1) OIL WARNING SYSTEM FIG.2 When the oil level falls below the lower level, the engine stops automatically. Unless you refill with oil, the engine will not start again. FIG.2 2) ENGINE SWITCH The engine switch controls the ignition system. FIG.3 ① RUN(on) Ignition circuit is switched on. The engine can be started. ② STOP Ignition circuit is switched off. The engine will not run. FIG.3 ③ START Starting circuit is switched on. The starter motor starts.
) OUTPUT RESET FIG.7 Push reset button for 2 seconds, the generator will recover the AC output when the generator stop producing AC output under overload protect. FIG.7 INSTRUCTIONS V A KW FOLLOW MODE TEST MONTHLY TEST MONTHLY FOLLOW HZ RESET NOTE: Reduce the load on the generator to ensure that the total load is within the generator’s rated output power. 8) AUTO GEN START FIG.
2) CHECK ENGINE OIL FIG.10 Make sure the engine oil is indicated by dip stick at the upper level of the oil filler hole. Add oil as necessary. FIG.10 Remove oil filler cap and check the engine oil level. If oil level is below the lower level line, refill with suitable oil to upper level line. Do not screw in the oil filler cap when checking oil level. Change oil if dirty. Oil capacity: (see page 15) Recommended engine oil: 10W-30 API Service SJ FIG.11 3) GROUND (Earth) FIG.
OPERATION FIG.14 NOTE: The generator has been shipped without engine oil. Fill with oil or it will not start. Do not tilt the generator when adding engine oil. This could result in overfilling and damage to the engine. FIG.15 INSTRUCTIONS V A KW FOLLOW TEST MONTHLY TEST MONTHLY MODE STARTING THE ENGINE FOLLOW HZ 1) NOTE: ON Before starting the engine, do not connect electric appliance. FIG.14 FIG.16 A Electric start ENGINE SWITCH 1. Turn the fuel cock lever to the ON position.
Be sure the outlet load current is within outlet’s rated current. The economy control switch must be turned to “OFF” when using electric FIG.20 ECON.SW devices that require a large starting current, such as a compressor or a ON submersible pump. FIG.20 OFF OVERLOAD INDICATOR LIGHT FIG.21 The overload indicator light comes on when overloaded, short circuit, or voltage is out of operating tolerance, or the AV output voltage rises.
(c) If DC breaker has popped or open, disconnect the device then press to Aim for specific gravity and charging time 1.30 reset and reconnect DC device. Specific gravity 20°C 1.26 2 1.22 1.18 3 1.14 1 1.10 1.06 0 2 4 6 8 10 chargong time Hr CAUTION: Be sure the economy control switch is turned off while charging the Battery capacity 1. 30AH 20HR 2. 35AH 20HR 3. 47AH 20HR FIG.24 battery. FIG.25 3) STOPPING THE ENGINE 1.
PERIODIC MAINTENANCE MAINTENANCE CHART Regular maintenance is important for the best performance and safe operation. Pre-operation Item Remarks Spark Check condition adjust gap and Plug clean. Replace if necessary. Engine Check oil level Oil Replace Oil filter Clean oil filter Air Filter Clean. Replace if necessary. Fuel Filter Clean fuel cock filter. Replace if necessary Choke Check choke operation Valve Check and adjust when engine Clearance is cold.
ENGINE OIL REPLACEMENT 1. FIG.28 Place the generator on a level surface and warm up the engine for several minutes. Then stop the engine and turn the fuel cock knob to OFF. Turn the fuel tank cap air vent knob clockwise. 2. Loosen the screw and remove the cover. FIG.28 3. Remove the oil filler cap. FIG.29 4. Place an oil pan under the engine. Tilt the generator to drain the oil FIG.29 completely. 5. Replace the generator on a level surface. 6. Add engine oil to the upper level of dip stick. 7.
CAUTION: FIG.31 The engine should never run without the element; excessive piston and/or cylinder wear may result. CLEANING AND ADJUSTING SPARK PLUG 1. Remove the cover. 2. Check for discoloration and remove the carbon. FIG.31 3. Check the spark plug type and gap. 4. Replace the spark plug. FIG.32 5. Attach the cover Standard electrode color: Tan Color Standard Spark Plug: F5RTC (TORCH) Spark Plug Gap: 0.6-0.7 mm (0.024-0.028 in) FUEL TANK FILTER 1. Remove the fuel tank cap and filter. FIG.32 2.
3. Use a flathead screw driver to pry the spark arrester out from the muffler. 4. Remove the carbon deposits on the muffler screen and spark arrester using a wire brush. FIG.34 5. Re-install the muffler screen. 6. Re-install the cover TROUBLE SHOOTING ENGINE WON’T START 1. Fuel systems No fuel supplied to combustion chamber. No fuel in tank….Supply fuel. Fuel in tank….Fuel tank cap air vent knob to “ON”, fuel cock knob to “ON” Clogged fuel line….Clean fuel line. Clogged carburetor….
STORAGE Long term storage of your generator will require some preventive procedures maintenance to guard against deterioration. DRAIN THE FUEL 1. Remove the fuel tank cap, drain the fuel from the fuel tank 2. Remove the cover, drain fuel from the carburetor by loosening the drain screw. ENGINE 1. Remove the spark plug, pour in about one tablespoon of SAE 10W30 or 20W40 motor oil into the spark plug hole and reinstall the spark plug. 2. Clean exterior of the generator and apply a rust inhibitor. 3.
SPECIFICATION MODEL GEN6600W240VS GENERATOR Type Inverter Generator AC Voltage 120/240V Frequency 60Hz Max. Output 6.6 kW Continuous Output 6 kW Power Factor 1.0 DC Output Model XY188F-1 Type Air-cooled, 4 cycle, OHV, Gasoline Engine Bore×Stroke ENGINE POWER OUTLET 12V / 5.0A / USB 5V/3.1A mm×mm 88×64 Displacement 389cc Max. Output 7.2kW / 3600rpm Fuel Unleaded Gasoline Fuel tank Capacity 18.
WIRING DIAGRAM CONTROL PANEL BLOCK GENERATOR BLOCK DC WINDING DC WINDING Bu Bu Bu Bu Bu Bu Bu Bu FUSE 15A Bu DC 12V OUTPUT DC PROTECTOR 6A BL RECTIFIER R RECTIFIER R BL GROUND TERMINAL DC5V3.1A R BL BL MAIN WINDING BL INVERTER UNIT BL BL BL W W W W BL BL AC 20A V-I-P-Hz AC 20A BL L14-30R MAIN WINDING 5-20R 5-20R BL BU R BL OUTPUT RESET R PI W SUB WINDING ECON.