User Guide

AIMS Power www.aimscorp.net
19
Important: If the battery temperature is allowed to fall to extremely cold temperatures, the inverter with a
BTS may not be able to properly recharge cold batteries due to maximum voltage limits of the inverter.
Ensure the batteries are protected from extreme temperatures.
For more detailed technical information, please contact us.
2.5.13 Other Features
Battery voltage recovery start
After low battery voltage shut off, the inverter is able to restore to work after the battery voltage recovers to
13V/26V/52V (with power switch still in “On” position). This function helps to save the users extra labor to
reactivate the inverter when the low battery voltage returns to acceptable range in renewable energy systems.
WARNING
Never leave the loads unattended, some loads (like a Heater) may cause accidents in such cases.
It is better to shut everything off after low voltage trip than to leave your load in the risk of fire.
Conformal Coating
The entire line of inverters has been processed with a conformal coating on the PCB, making it water, rust,
and dust resistant.
While these units are designed to withstand corrosion from the salty air, they are not splash proof.
3 Installation
3.1 Unpacking and Inspection
Carefully remove the inverter/charger from its shipping package and inspect all contents.
Verify the following items are included:
·The PICOGLF Inverter/Charger
·Red and black DC terminal covers
·AC terminal block cover with two Phillips screws
·Two Flange nuts and 4 Phillips screws (installed on the DC terminals).
·PICOGLF Series Owners Manual
If items appear to be missing or damaged, contact our authorized dealer or us. If at all possible, keep your
shipping box. It will help protect your inverter from damage if it ever needs to be returned for service. Save
your proof-of-purchase as a record of your ownership; it will also be needed if the unit should require
warranty work.
3.2 Installation Location, Tools & Materials
Follow all the local regulations to install the inverter.
Please install the equipment in an INDOOR location of Dry, Clean, Cool with good ventilation.
Working temperature: -10 to 40(-14to 104)
Storage temperature: -40 to 70(-40to 158)