AIMS Power www.aimscorp.net
30
Remote Control
Yes. Optional
Bypass &
Protection
Input Voltage Waveform
Sine wave (Grid or Generator)
Nominal Voltage
120Vac
Low Voltage Trip
80V/90V±4%
Low Voltage re engage
90V/100V±4%
High Voltage Trip
140V±4%
High Voltage re engage
135V±4%
Max Input AC Voltage
150VAC
Nominal Input Frequency
50Hz or 60Hz (Auto detect)
Low Freq Trip
Narrow: 47±0.3Hz for 50Hz, 57±0.3Hz for 60Hz
Wide:40±0.3Hz for 50Hz/60Hz
Low Freq re engage
Narrow: 48±0.3Hz for 50Hz, 58±0.3Hz for 60Hz
Wide:45±0.3Hz for 50Hz/60Hz
High Freq Trip
Narrow: 55±0.3Hz for 50Hz, 65±0.3Hz for 60Hz
Wide: No up limit for 50Hz/60Hz
High Freq re engage
Narrow: 54±0.3Hz for 50Hz, 64±0.3Hz for 60Hz
Wide: No up limit for 50Hz/60Hz
Output Short circuit protection
Circuit breaker
Bypass breaker rating (120Vac)
20A
20A
30A
40A
GFCI Ranting
10A
15A
15A
15A
Mechanical
Specification
Mounting
Wall/Ground mount
Inverter Dimensions(L*W*H)
390*241*179mm
15*11*7”
Inverter Weight
16.5KG
17KG
20.5KG
26.3KG
37.48 lbs
Shipping Dimensions(L*W*H)
530*490*315mm
Shipping Weight
18.8KG
19KG
22.5KG
28.3KG
41.89 lbs
Display
Status LEDs/Remote LCD Display
Standard Warranty
1 Year